Enabled the door will prevent any exit if the outside area is armed.<br />

Disabled the outside area will not affect the access decision.<br />

Option 6 – Disable Door Open Alarms if unlocked on Schedule, Latch or Area Status<br />

Enabled the door will not generate the door left open alarm events to the<br />

reader expanders beeper and led ports if they are programmed. This allows<br />

a door to be “propped” open during normal opening times however a prealarm<br />

warning will still be generated.<br />

This option DOES NOT prevent the door left open trouble zone from<br />

being sent to the monitoring station if reporting on the trouble zone<br />

is programmed to be generated. To prevent the door open alarms<br />

from being sent schedule the zone type for the door open alarm<br />

events to operate without reporting during the day.<br />

Disabled the door open alarm events operate normally.<br />

Option 7 – Prompt User Access Type<br />

Enabled the user will be prompted on the reader expanders ascociated<br />

keypad to enter their reason for access. The user must enter the reason<br />

before access will be granted.<br />

Disabled no prompt will be displayed.<br />

Option 8 - Generate User Access Taken Events<br />

Enabled the door will generate a User Access Taken event if the door opens<br />

while the door is unlocked after entry has been granted. If the door<br />

remains closed an Access Not Taken event will be generated.<br />

Disabled no event will be generated.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Door Type<br />

Each door type is assigned a unique door type address. There are four default door types that<br />

will cover nearly all the configurable options. To access door type programming, login using a<br />

valid code that has access to the door type programming menu and then select [MENU, 5,<br />

2]. The screen will then prompt you to "Select a door type to modify" requesting that you<br />

enter a door type number. Type the appropriate 3-digit door type number or use the [] and<br />

[] keys to scroll the available door types.<br />

Door type to<br />

modify: DT001<br />

When the desired door type number appears on the screen, press [ENTER] to program the<br />

selected door type. The maximum number of door types that can be programmed is limited<br />

by your system’s memory and configured profile.<br />

To browse the door types by name press [ENTER] when prompted for a door type number to<br />

modify and then use the [] and [] keys to scroll the available door types by their name.<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />