If there is no schedule programmed and the door is to follow the<br />

area status you must set the OR option to enable the area status to<br />

be processed. You also MUST select an inside or outside area.<br />

Disabled the door will perform no OR logic processing for the schedule and<br />

area status.<br />

Option 8 – Generate REX/REN Access Taken Events<br />

Enabled the door will generate a Request to Exit (or Enter) event if the door<br />

opens while the door is unlocked from a request to exit. If the door remains<br />

closed an Access Not Taken event will be generated<br />

Disabled no event will be generated.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Extra Options<br />

Extra options include only the user area control option with most of these being reserved.<br />

DR001 Extra<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Update User Area When Door Has No Anti Pass Back<br />

Enabled the door will update the users current area even if the door is not<br />

programmed with card anti pass back. This can be used to keep track of the<br />

user's last area that they entered.<br />

Disabled the users area will not be modified if the door is not programmed<br />

for card anti pass back control.<br />

Option 2 – Prevent Request To Exit If Inside Area Armed<br />

Enabled the door will deny a request to exit when the inside area has been<br />

armed to prevent egress from an armed area.<br />

Disabled the request to exit operates during any inside area state.<br />

Option 3 – Enable ADA Lock Output<br />

Enabled the door will multiply the lock output time by two for any user that<br />

has been tagged as an ADA (American Disabilities Act) user allowing an<br />

extended amount of time for access and door left open.<br />

Disabled the ADA option has no affect on the door lock time.<br />

Option 4 – Deny Entry if Inside Area Armed<br />

Enabled the door will deny any entry if the inside area is armed.<br />

Disabled the inside area will not affect the access decision.<br />

Option 5 – Deny Exit if Outside Area Armed<br />

181 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>