Forced Open PGM Pulse ON Time<br />

The forced open PGM pulse on time is used to make the PGM output pulse on and off when<br />

activated. The value entered here must be greater than 0 and is in increments of 100ms. For<br />

example setting 10 will pulse the unit on for 1 second and then off for the programmed time<br />

set in the pulse off section.<br />

DR001 Forced<br />

time: 000 on<br />

To modify the forced open pulse on time (000 to 255 100ms Increments), use the keypad as<br />

explained in section Entering Decimal Numbers on Page 405 and press [ENTER]. Both the on<br />

and off pulse settings must have a value greater than 000 for this feature to operate.<br />

Forced Open PGM Pulse OFF Time<br />

The forced open PGM pulse off time is used to make the PGM output pulse on and off when<br />

activated. The value entered here must be greater than 0 and is in increments of 100ms. For<br />

example setting 10 will pulse the unit off for 1 second and then on for the programmed time<br />

set in the pulse on section.<br />

DR001 Forced<br />

time: 000 off<br />

To modify the forced open pulse off time (000 to 255 100ms Increments), use the keypad as<br />

explained in section Entering Decimal Numbers on Page 405 and press [ENTER]. Both the on<br />

and off pulse settings must have a value greater than 000 for this feature to operate.<br />

Miscellaneous Options<br />

Miscellaneous options for the door include the control of events that are generated and the<br />

function of the door schedule.<br />

DR001 Misc<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Check Schedule Each Minute<br />

Enabled the door will revalidate the unlock schedule that it is assigned each<br />

minute. This will prevent the door from being controlled and locked when it<br />

should be unlocked.<br />

This option also prevents schedule and area control from operating<br />

correctly and if enabled will prevent the follow inside and follow<br />

outside area status from operating. Setting this option will allow the<br />

prevent unlock on arming and normal scheduling operations to<br />

occur.<br />

Disabled the schedule will operate normally and be checked at the start and<br />

end times.<br />

Option 2 - Door Open Event When On Schedule<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />