Door Lock PGM or PGM Group<br />

You can assign a PGM or PGM group that controls the physical electric lock for the door. This<br />

is typically the lock control PGM on the <strong>PRT</strong>-RDI2 reader expander that is being used to<br />

control the door.<br />

DR001 Door Lock<br />

pgm: --000:00<br />

To modify the door lock PGM or PGM Group, use the settings as explained in section Entering<br />

PGM and PGM Groups on Page 410.<br />

Pre Alarm PGM or PGM Group<br />

You can assign a PGM or PGM group that will activate when the pre-alarm time that is<br />

programmed is reached. Use this to warn users that the door will generate an alarm if it is left<br />

open any longer.<br />

DR001 Pre Alarm<br />

pgm: --000:00<br />

To modify the pre alarm PGM or PGM Group, use the settings as explained in section Entering<br />

PGM and PGM Groups on Page 410.<br />

Pre Alarm PGM Pulse ON Time<br />

The pre alarm PGM pulse on time is used to make the PGM output pulse on and off when<br />

activated. The value entered here must be greater than 0 and is in increments of 100ms. For<br />

example setting 10 will pulse the unit on for 1 second and then off for the programmed time<br />

set in the pulse off section.<br />

DR001 Pre Alarm<br />

time: 000 on<br />

To modify the pre alarm on time (000 to 255 100ms Increments), use the keypad as<br />

explained in section Entering Decimal Numbers on Page 405 and press [ENTER]. Both the on<br />

and off pulse settings must have a value greater than 000 for this feature to operate.<br />

Pre Alarm PGM Pulse OFF Time<br />

The pre alarm PGM pulse off time is used to make the PGM output pulse on and off when<br />

activated. The value entered here must be greater than 0 and is in increments of 100ms. For<br />

example setting 10 will pulse the unit off for 1 second and then on for the programmed time<br />

set in the pulse on section.<br />

DR001 Pre Alarm<br />

time: 000 off<br />

To modify the pre alarm pulse off time (000 to 255 100ms Increments), use the keypad as<br />

explained in section Entering Decimal Numbers on Page 405 and press [ENTER]. Both the on<br />

and off pulse settings must have a value greater than 000 for this feature to operate.<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />