DR001 Slave<br />

None<br />

Use the [1] and [3] keys to scroll the slave door selection and press [ENTER] to select the<br />

slave door displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406. Setting a slave door that is the same as the door<br />

being programmed will have no affect.<br />

Interlocking Group<br />

The interlocking group is assigned to a door that can not opened or accessed when any of the<br />

doors assigned in the interlocking group are not secure. Access will be denied to the user<br />

based on an interlock.<br />

DR001 Interlock<br />

None<br />

Use the [1] and [3] keys to scroll the interlock door group selection and press [ENTER] to<br />

select the interlock door group displayed. For more information about the list control data<br />

entry refer to the section List Control Data Entry on Page 406.<br />

Inside Area<br />

The inside area defines which area is on the inside of this door. This is used to prevent a user<br />

from gaining access to a door when the area is armed and they can not disarm it as well as<br />

automatically disarming the area when the door is accessed. Using the door and area control<br />

integrates the two systems and is an ideal solution to false alarm prevention.<br />

DR001 Inside<br />

None<br />

Use the [1] and [3] keys to scroll the inside area selection and press [ENTER] to select the<br />

inside area displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Outside Area<br />

The outside area defines which area is on the outside of this door. This is used to prevent a<br />

user from gaining access to a door when the area is armed and they can not disarm it as well<br />

as automatically disarming the area when the door is accessed. Using an inside and an<br />

outside area usually requires that the door is programmed with both an entry and exit reader.<br />

DR001 Outside<br />

None<br />

Use the [1] and [3] keys to scroll the outside area selection and press [ENTER] to select the<br />

outside area displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Lock Schedule<br />

The lock schedule determines when this door will unlock at a scheduled time. For example an<br />

employee entry door may require to be unlocked at 7am and locked at 5pm you would assign<br />