Option 6 - Banking Vault Dual Control Area<br />

Enabled the area will require that two users control this area when enabled<br />

as a vault control area. This feature will not function unless the area has<br />

option 5 enabled.<br />

Disabled the area will require only one code to control the vault control<br />

functions.<br />

Option 7 - Prevent Arming if Count is Not Zero<br />

Enabled the area will be prevented from arming if the count value for the<br />

area is greater than 0.<br />

Disabled the area will arm regardless of the count value.<br />

Option 8 - Validate Schedule Each Minute<br />

Enabled the area will verify that the programmed schedule has not changed<br />

or the area has not be disarmed when it should be armed. This will occur<br />

every one minute period.<br />

Disabled the area does not check the schedule each minute. If the schedule<br />

is programmed the schedule is validated when the start time is reached and<br />

when the end time is reached and does not take in to account the control of<br />

the area outside these times.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Area Special Options<br />

The special options include a number of specific options that may be required in special<br />

circumstances.<br />

AR001 Special<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 – Defer Automatic Arming<br />

Enabled the area will begin a defer arming cycle prior to starting to arm the<br />

area when the area is set to automatically arm on schedule.<br />

Disabled the area will arm normally.<br />

Option 2 – Force Arm Card Reader<br />

Enabled the area will force arm the area when the arming process is started<br />

by a card reader.<br />

Disabled the area will arm normally.<br />

Option 3 – Disable Exit PGM on Stay<br />