Area Reporting Options<br />

Reporting options for the area include the settings for the reporting events and some specific<br />

options for the control counting options.<br />

AR001 Report<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Report Closing (Arming) Area<br />

Enabled the area will generate a reportable event that can be directed to a<br />

monitoring station.<br />

Disabled the area will not generate an event when it is closed (armed).<br />

Option 2 - Report Opening (Disarming) Area<br />

When enabled the area will generate a reportable event that can be sent to<br />

a monitoring station.<br />

Disabled the area will not generate an event when it is opened (disarmed).<br />

Option 3 - Report Control of the 24HR Tamper Area<br />

Enabled the area will report both an opening (Disabled) or closing<br />

(Enabling) of the 24HR section of this area.<br />

Disabled the 24HR Tamper Area will not report any enable or disable<br />

messages.<br />

Option 4 - Report Bypassed Zones<br />

Enabled the area will report all zones that are bypassed once it completes<br />

the arming process.<br />

Disabled the area will not report any bypass zones.<br />

Option 5 - User Counting<br />

Enabled the users that access this area will be counted using the area<br />

counting function.<br />

Disabled the area will not perform any counting.<br />

Option 6 - Arm On Count Reaching 0<br />

Enabled the area will arm when the count in the area reaches the terminal 0<br />

count.<br />

Disabled the area will not perform any function on the count reaching 0.<br />

Option 7 - Report Entry Zones Immediately<br />

167 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>