01.07.2014 Views

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

AR001 Lock Dr Gp<br />

None<br />

Use the [1] and [3] keys to scroll the door group selection and press [ENTER] to select the<br />

door group displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Normal Disarm Schedule<br />

The normal disarm schedule defines the times when the area should be disarmed. This is<br />

used to generate the Early/Late to Disarm Events (see Special Options on Page 169 to enable<br />

these events). The first period programmed that is valid for the current day will be used as<br />

the normal disarm time slot.<br />

To have the System <strong>Controller</strong> send a reportable event when an area is not disarmed between<br />

0715 and 0745 on Monday to Friday and between 0815 and 0845 on Saturday create a new<br />

schedule with the settings as shown in Table 1 and the select option 6 (Early/Late Disarm<br />

Report) in the Area Special options.<br />

Period Start End<br />

Days<br />

S M T W T F S<br />

1 0715 0745 * * * * *<br />

2 0815 0845 *<br />

3<br />

4<br />

Table 1 - Normal Disarm Schedule Example Programming<br />

If the area is disarmed before 0715 an Early to Disarm event will be generated when the area<br />

is disarmed. At 0745 if the area is not disarmed the system will generate a Late to Disarm<br />

event.<br />

AR001 Nor Disarm<br />

None<br />

Use the [1] and [3] keys to scroll the schedule selection and press [ENTER] to select the<br />

schedule displayed. For more information about the list control data entry refer to the section<br />

List Control Data Entry on Page 406.<br />

Normal Arm Schedule<br />

The normal arm schedule defines the times when the area should be armed. This is used to<br />

generate the Early/Late to Arm Events (see Special Options on Page 169 to enable these<br />

events). The first period programmed that is valid for the current day will be used as the<br />

normal arm time slot.<br />

To have the System <strong>Controller</strong> send a reportable event when an area is not armed between<br />

1715 and 1745 on Monday to Friday and between 1515 and 1545 on Saturday create a new<br />

schedule with the settings as shown in Table 1 and the select option 7 (Early/Late Arm<br />

Report) in the Area Special options.<br />

Period Start End<br />

Days<br />

S M T W T F S<br />

1 1715 1745 * * * * *<br />

2 1515 1545 *<br />

3<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />

164

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!