AR001 Defer arm<br />

time: 000 off<br />

To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in<br />

section Entering Decimal Numbers on Page 405 and press [ENTER]. Both the on and off pulse<br />

settings must have a value greater than 000 for this feature to operate.<br />

Defer Arming Warning Time<br />

The defer arming warning time sets the time that the area will warn the user that it is about<br />

to arm and that they need to defer the arming (login and press the Disarm Key).<br />

AR001 Defer warn<br />

time: 000 off<br />

To modify the defer warning time (000 to 255 Minutes), use the keypad as explained in<br />

section Entering Decimal Numbers on Page 405 and press [ENTER].<br />

Defer Keypad Display Group<br />

The defer keypad group is used to display that an area is about to arm on the keypads that<br />

belong to the keypad group. The keypads will display this message provided they do not have<br />

any higher priority messages that are being displayed. The keypad beeper is recommended to<br />

be programmed in the defer PGM output group.<br />

For the Defer Keypad group to generate a message the keypad must also be programmed<br />

with the Display Defere Messages.<br />

AR001 Defer Grp<br />

None<br />

Use the [1] and [3] keys to scroll the keypad group selection and press [ENTER] to select the<br />

keypad group displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Client Code<br />

The client code for the area is the code that will be used to report alarms to the monitoring<br />

station. If the client code is left at the default value of FFFF then the client code that will be<br />

used is the client code assigned in the service that is being used to report the alarms.<br />

AR001 Client<br />

code: FFFF<br />

To modify the client code setting (0000 to FFFF hexadecimal), use the keypad as explained in<br />

section Entering Hexadecimal Numbers on Page 408 and press [ENTER].<br />

Lock Door Group on Arming<br />

When programmed this door group will be locked before the arming process starts. This<br />

helps to ensure that any door left open zones are closed as the associated doors are locked<br />

and the area will be able to arm successfully.<br />

163 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>