AR001 Name<br />

*Area 001<br />

To scroll areas by name use the [] and [] keys. To modify or enter a new name for the<br />

selected area use the keypad as explained in section Entering Text and Names on Page 406<br />

and press [ENTER].<br />

By default the area name will be prefixed by an '*' this indicates that the name is an editable<br />

name in the system. Some areas do not have names, this is limited by the system memory<br />

and the profile configured.<br />

Area Entry Delay Time<br />

Setting an entry delay time for the area allows users that have entered a secured point to<br />

have time to disarm the area before the area generates an alarm. Only zones that have a<br />

zone type assigned with an entry delay option set will start the entry delay timer for the area.<br />

AR001 Entry<br />

time: 060 secs<br />

To enter a entry delay time (000 to 250), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER].<br />

Area Exit Delay Time<br />

Setting an exit delay time for the area allows users to exit the area once the arming of the<br />

area has begun without triggering an alarm. Zones that are part of the exit route should be<br />

programmed with the exit option in the assigned zone type.<br />

AR001 Exit<br />

time: 030 secs<br />

To enter a exit delay time (000 to 250), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER]. An exit delay time of 000 seconds will<br />

result in the area arming instantly.<br />

Area Siren Bell Time<br />

The bell time determines how long the bell/siren output for the area will remain activated<br />

before timing out. If the option to retrigger the bell time is set in the zone type assigned to a<br />

zone that is triggered in the area the siren bell time is reloaded on each subsequent alarm<br />

activation.<br />

Use the siren bell time and the retrigger bell option from the zone type for smart automation<br />

of lighting and building control.<br />

AR001 Bell<br />

time: 004 mins<br />

To enter a bell siren time (000 to 250 minutes), use the keypad as explained in section<br />

Entering Decimal Numbers on Page 405 and press [ENTER]. A bell siren time of 000 will<br />

result in no siren or bell activation.<br />

151 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>