Type the appropriate module type, module address and PGM number or use the [] and []<br />

keys to scroll the available PGM's. When the desired PGM number appears on the screen,<br />

press [ENTER] to program the selected PGM number.<br />

PGM Name<br />

If the selected PGM has a name associated (some PGM's do not have a name associated with<br />

them) the name programming screen will be shown.<br />

CP001:01 Name<br />

*PGM CP001:01<br />

To scroll PGM's by name use the [] and [] keys. To modify or enter a new name for the<br />

selected PGM use the keypad as explained in section Entering Text and Names on Page 406<br />

and press [ENTER].<br />

By default the PGM name will be prefixed by an '*' this indicates that the name is an editable<br />

name in the system.<br />

Activation Schedule<br />

The activation schedule is programmed to activate the PGM at a certain time of the day or to<br />

activate the PGM between certain hours. The schedule will be checked at the start and end<br />

times and if the start is valid the PGM will be activated, if the end time of the schedule is valid<br />

the PGM will be deactivated.<br />

If a PGM is controlled by an operator, user or other function during this activation time and is<br />

deactivated it will remain in the deactivated state. Setting the recheck schedule option for the<br />

PGM will force the PGM to have the schedule verified every 60 second period. This will prevent<br />

the PGM from being controlled manually as the schedule will override the manual operation.<br />

CP001:01 Sched<br />

None<br />

Use the [1] and [3] keys to scroll the schedule selection and press [ENTER] to select the<br />

schedule displayed. For more information about the list control data entry refer to the section<br />

List Control Data Entry on Page 406.<br />

PGM Activation Time<br />

Setting an activation time for a PGM will mean that any device controlling the PGM will only<br />

activate the PGM for the programmed time. Use the activation time to program school bells<br />

and lunch or break time signalling in factories.<br />

CP001:01 Pgm<br />

time: 00000 secs<br />

To enter a activation time (00000 to 65535), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER].<br />

PGM Miscellaneous Options<br />

Miscellaneous options for the PGM include the configuration of event logging, schedule and<br />

power up configurations for the PGM.<br />