Option 1 – Always Log Zone Event<br />

Enabled the zone will always log an event when it changes state. Using this<br />

feature can allow a zone to have one area armed permanently for<br />

automation events without it creating events in the event buffer, but when<br />

the alarm area is armed events can still be generated. Note that the zone<br />

option “Log Zone Events” will override this option.<br />

Disabled the zone not generate events.<br />

Option 2 to 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

Reporting Code<br />

Each zone type has a default reporting code already assigned which determines the code that<br />

is sent to the central station when an alarm is generated refer to the Contact ID Codes table<br />

on Page 381. However, it is possible to change the reporting code of the zones to which this<br />

zone type is assigned. This is used when using special reporting formats for example ModBUS<br />

Remote uses this to identify special zone points to the remote Protégé System <strong>Controller</strong>.<br />

ZT001 Report<br />

code: 255<br />

To enter a reporting code (000 to 254), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER]. By default the Zone Type Reporting Code<br />

is set to 255. Setting a value of 255 uses the default reporting code for the zone assigned.<br />

Control PGM or PGM Group<br />

You can assign a PGM or PGM group to activate whenever a zone type process's an alarm or<br />

restore for a zone. The zone type must have the control PGM options set in the PGM options.<br />

ZT001 Control<br />

pgm: --000:00<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and<br />

PGM Groups on Page 410.<br />

Control PGM Activation Time<br />

You can override the programmed activation time for a PGM by setting an activation time in<br />

the zone type.<br />

ZT001 PGM on<br />

time: 00000 secs<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and<br />

PGM Groups on Page 410.<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />