time programmed no time will be used.<br />

Disabled the zone will activate using the PGM timer if it is set to a value<br />

greater than 0.<br />

Option 2 - Activate Control PGM On Alarm<br />

Enabled the zone type will activate the zone control PGM when the zone<br />

assigned generates an alarm.<br />

Disabled the zone type takes no action on the control PGM.<br />

Option 3 - Activate Control PGM On Restore<br />

Enabled the zone type will activate the zone control PGM when the zone<br />

assigned restores from an alarm.<br />

Disabled the zone type takes no action on the zone control PGM.<br />

Option 4 - Deactivate Control PGM On Alarm<br />

Enabled the zone type will de-activate the zone control PGM when the zone<br />

assigned generates an alarm.<br />

Disabled the zone type takes no action on the zone control PGM.<br />

Option 5 - Deactivate Control PGM On Restore<br />

Enabled the zone type will de-activate when the zone control PGM assigned<br />

restores from an alarm.<br />

Disabled the zone type takes no action on the zone control PGM.<br />

Option 6 – Toggle Zone Control PGM On Restore<br />

Enabled the zone control PGM will be toggled when the zone goes in to<br />

alarm. You can use this option to activate a PGM on alarm and deactivate on<br />

the next alarm. This is ideal for lighting control and automation applications.<br />

Disabled the zone type takes no action on the zone control PGM.<br />

Option 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Zone Control Extra Options<br />

Zone Type Extra options for the zone type, configure extended options for the zone type.<br />

ZT001 Extra<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />