Option 8 - Activate Entry PGM For Bell Siren Time Duration<br />

Enabled the zone type will activate the entry PGM programmed for the area<br />

for the duration of the bell siren time.<br />

Use this feature for a zone that you want to only generate a beeper alarm<br />

and assign the entry PGM a keypad beeper pgm. This option will not<br />

function if the bell option is enabled.<br />

Disabled the zone type operates normally.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Zone Type PGM Options<br />

PGM options for the zone type configure options for various functions that control the PGM's<br />

programmed in a zone type.<br />

ZT001 Pgm Ctrl<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Activate Bypass PGM<br />

Enabled the zone type will activate bypass PGM for the area if a zone is<br />

bypassed.<br />

Disabled the zone type will not activate the bypass PGM.<br />

Option 2 - Activate Tamper PGM<br />

Enabled the zone type will activate the tamper PGM for the area if a tamper<br />

alarm occurs.<br />

Disabled the zone type will not activate the tamper PGM.<br />

Option 3 - Activate Memory PGM<br />

Enabled the zone type will activate the memory PGM for the area if an alarm<br />

occurs.<br />

This option can be used to indicate that an alarm has occurred in the<br />

system. Use this feature to display an indication to the users of the<br />

system to prevent possible "Sitter and Hostage" situations.<br />

Disabled the zone type will not activate the memory PGM when an alarm<br />

occurs.<br />

Option 4 - Activate Control PGM On Alarm<br />

Enabled the zone type will activate the control PGM when the zone assigned<br />

generates an alarm.<br />

Disabled the zone type takes no action on the control PGM.<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />