ZT001 Misc<br />

[1-3-----]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Generate Siren Bell Output<br />

Enabled the zone type will activate the siren bell output programmed for the<br />

area.<br />

Disabled the zone type will not generate a bell output.<br />

Option 2 - Restart Siren Bell Timer<br />

Enabled the zone type will restart the bell timer on each subsequent alarm.<br />

Disabled the zone type will not alter the bell timer if it is already active.<br />

Option 3 - Save Alarm to Memory<br />

Enabled the zone type will save an alarm message to the area's alarm<br />

memory storage area.<br />

Disabled the zone type does not save an alarm message.<br />

Option 4 - Disarm Control Area on Restore<br />

Enabled the zone type will disarm the control area when a zone assigned<br />

the zone type restores from an alarm condition.<br />

Use this feature and the arming control area feature as a on and off key<br />

switch arming input.<br />

Disabled the zone type takes no action on the control area.<br />

Option 5 - Arm Control Area on Alarm<br />

Enabled the zone type will start arming the control area when a zone<br />

assigned the zone type generates an alarm condition.<br />

Disabled the zone type takes no action on the control area.<br />

Option 6 - Toggle Control Area State On Alarm<br />

Enabled the zone type will toggle the state of the control area when the<br />

zone that is assigned this zone type generates an alarm.<br />

Disabled the zone type operates normally.<br />

Option 7 - Force Arm Tamper<br />

Enabled the zone type will allow the zone to be force armed if the zone<br />

assigned the zone type is tampered.<br />

Disabled the zone type operates normally.<br />

139 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>