Enabled the zone type will generate a reportable tamper message.<br />

Disabled the zone type does not generate a reportable tamper message.<br />

Option 3 - Report Bypass<br />

Enabled the zone type will generate a reportable bypass message.<br />

Disabled the zone type does not generate a reportable bypass message.<br />

Option 4 - Report Restore<br />

Enabled the zone type will generate a reportable restore message.<br />

Disabled the zone type does not generate a reportable restore message.<br />

Option 5 - Stay Zone<br />

Enabled the zone type will generate an alarm if the area is armed in stay<br />

mode. The zone will stay armed. For zones that will be active when an area<br />

is armed in stay mode it is recommended to disable the event log for the<br />

zone.<br />

Disabled the zone type operates normally.<br />

Option 6 - Force Zone<br />

Enabled the zone type will allow the zones it is assigned to be force armed.<br />

Disabled the zone type operates normally.<br />

Option 7 - No Exit Test<br />

Enabled the zone type will not verify the status of a zone prior to the area<br />

starting to arm. Use this feature to assign zones in exit locations to prevent<br />

the area from generating a zone open warning when being armed.<br />

Disabled the zone type operates normally.<br />

Option 8 - Recycle Zone On Exit Delay<br />

Enabled the zone type will recheck the zones it is assigned when the area<br />

completes the exit delay cycle and if a zone is open recycle the zone to<br />

force it in to generating an alarm.<br />

Use this feature for a zone type used on a zone that may be<br />

breached during the exit delay such as a window or door contact.<br />

Disabled the zone type operates normally.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />