Enabled the zone type will allow this zone to generate alarms during the exit<br />

delay however it will generate an alarm if the alarm condition occurs outside<br />

the exit delay period.<br />

Use this feature to prevent 'Sitters' from re-entering a building that is<br />

assumed to be secure during a long arming process.<br />

Disabled the zone type operates normally.<br />

Option 6 - Shorten Exit Delay Timer On Restore<br />

Enabled the zone type will shorten the exit delay timer on an area to five<br />

seconds when the zone restores.<br />

Use this feature to reduce the arming time of an area.<br />

Disabled the zone type operates normally.<br />

Option 7 - 24HR Alarm<br />

Enabled the zone type will generate a 24HR alarm if the zone generates an<br />

alarm. The area state will not affect the generation of this alarm.<br />

Disabled the zone type operates normally.<br />

Option 8 - Fire Alarm<br />

Enabled the zone type will generate a fire alarm when it is activated. This<br />

zone type will also operate similar to the 24HR Alarm option.<br />

Most smoke detectors use a normally open contact so any zone that is<br />

assigned this option must have the inverted state option selected and the<br />

EOL resistors option enabled.<br />

Disabled the zone type operates normally.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Zone Type Report Options<br />

Reporting options for the zone type configure the operation of the zone type when reporting<br />

to a communication service and includes options for various other zone type options.<br />

ZT001 Report<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Report Alarm<br />

Enabled the zone type will generate a reportable alarm message.<br />

Disabled the zone type does not generate a reportable alarm message.<br />

Option 2 - Report Tamper<br />

137 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>