When enabled the zone will be prevented from being bypassed if it is<br />

already assigned to an area that has either the 24HR processing enabled or<br />

the area is armed.<br />

Disabled the zone can be bypassed while it is in an armed condition. This<br />

option is not recommended unless it is required for a specific reason.<br />

Option 2, 3, 4, 5, 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Trouble Zone Trouble Group<br />

The high level of flexibility that is provided with the Protégé System allows the definition of<br />

the trouble type and group that is generated by a trouble zone. Troubles are grouped by a<br />

trouble group and then a trouble type within the group. When the trouble zone generates an<br />

alarm it will also generate the appropriate trouble condition that is configured. The trouble<br />

group and type are used to generate trouble conditions on the keypad and to prevent an area<br />

from Arming based on the trouble condition. To view the trouble conditions that are on the<br />

panel select the View Menu and select the Trouble View option refer to the View Menu on<br />

Page .<br />

CP001:01 Group<br />

System Trouble<br />

Use the [1] and [3] keys to scroll the available trouble groups that can be assigned to the<br />

trouble zone. For more information about the list control data entry refer to the section List<br />

Control Data Entry on Page 406.<br />

Group<br />

General Trouble<br />

System Trouble<br />

Access Trouble<br />

Description<br />

The General Trouble group consists of the trouble types that are<br />

part of the main system operation. Trouble conditions such as AC<br />

Failure, Real Time Clock and Bell Output Troubles belong to this<br />

group and are assigned the General Trouble Group and the<br />

appropriate trouble type from the group by default.<br />

The System Trouble group is used for module related system<br />

messages, hardware faults and other system conditions that do<br />

not belong in the general trouble group.<br />

The Access Control trouble group consists of the trouble conditions<br />

that are related to access control and door operation these include<br />

door forced open, door left open and number of attempts are some<br />

of the trouble types.<br />

Trouble Zone Trouble Type<br />

When a trouble zone is assigned to a trouble group it can then have a trouble type within the<br />

group assigned.<br />

CP001:01 Type<br />

Module Tamper<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />

130

Hooray! Your file is uploaded and ready to be published.