Zone Special Options<br />

Special options for the zone include the configuration of special bypass and wiring settings for<br />

the zone.<br />

CP001:01 Special<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Tamper Bypass Allowed<br />

Enabled the zone will bypass the tamper monitoring of the zone at the time<br />

the zone is bypassed.<br />

Disabled the zone will only bypass the alarm states and a tamper alarm or<br />

short will generate a tamper alarm.<br />

Option 2 - No Bypass When Area Armed<br />

When enabled the zone will be prevented from being bypassed if it is<br />

already assigned to an area that has either the 24HR processing enabled or<br />

the area is armed.<br />

Disabled the zone can be bypassed while it is in an armed condition. This<br />

option is not recommended unless it is required for a specific reason.<br />

Option 3 - Zone Uses EOL Resistors<br />

Enabled the zone will use the 2 EOL resistor wiring configuration.<br />

Disabled the zone will use no EOL resistors.<br />

Option 4, 5, 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Zone Reporting Id<br />

The Zone Reporting Id allows the installer to program any reporting number to any zone. This<br />

provides an extremely high level of flexibility to assign true reporting numbers to the zones. A<br />

zone that is assigned the same reporting ID as another zone will result in both the zones<br />

reporting that ID.<br />

If a zone is assigned an ID number that is higher than the maximum number that can be<br />

reported by a particular service, the service will use the maximum number that can be<br />

assigned for that format.<br />

CP001:01 Report<br />

id: 00000<br />