The zone will still perform all functions that are programmed if this is not<br />

enabled. When using zones as automation zones it is recommended to<br />

disable the event logging option to reduce the impact on the event log<br />

buffer.<br />

Disabled the zone will not log an event.<br />

Option 2 - Trouble Condition Display<br />

When enabled the zone will be monitored for a trouble condition and cause<br />

a trouble alarm to be generated. The trouble will be generated only if the<br />

zone is either shorted or tampered.<br />

Disabled the zone is not monitored for trouble conditions.<br />

Option 3 - Bypassing Not Allowed<br />

Enabled the zone is a high security zone and cannot be bypassed.<br />

However, the zone can still be force armed if the Force Arming option is<br />

turned on. In order to avoid this, and to insure that the zone is not ignored<br />

when force arming, the Zone Force Arming option should be turned off in<br />

the zone type that is assigned to the zone.<br />

Disabled the zone can be bypassed.<br />

Option 4 - Bypassing Latched Not Allowed<br />

Enabled the zone is a high security zone and cannot be latch bypassed<br />

(Permanent<br />

Bypass).<br />

However, the zone can still be force armed if the Force Arming option is<br />

turned on. In order to avoid this, and to insure that the zone is not ignored<br />

when force arming, the Zone Force Arming option should be turned off.<br />

Disabled the zone can be latch bypassed.<br />

Option 5 - Zone State Inverted<br />

Enabled the zone the will operated in an inverted mode. By default all zones<br />

are normally closed, setting this option will change the zone to normally<br />

open.<br />

At least one zone open and close is needed to correctly update the zone<br />

state.<br />

Disabled the zone will operate normally.<br />

Option 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

123 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>