ZONE INPUTS<br />

Introduction<br />

To access the zone programming, login using the valid installer code and then select [MENU,<br />

4, 2, 1] for zone programming, [MENU, 4, 2, 2] for trouble zone programming and [MENU,<br />

4, 2, 3] for zone type programming. The Zones menu enables you to set up and program all<br />

the zones in your system.<br />

MENU 4, 2<br />

ZONE<br />

PROGRAMMING<br />

MENU 4, 2, 1<br />

ZONE<br />

PROGRAMMING<br />

MENU 4, 2, 2<br />

TROUBLE ZONE<br />

PROGRAMMING<br />

MENU 4, 2, 3<br />

ZONE TYPE<br />

PROGRAMMING<br />

Zone<br />

Figure 7 - Zone Inputs Menu Overview<br />

Zones and trouble zones can only be programmed when the areas they are assigned<br />

to and the area’s 24hr processing are disarmed/disabled, refer to the Arm and<br />

Disarm Operations on Page 33. If the area or the associated 24hr processing is<br />

armed/enabled, you can only view the screens, but not modify the information they<br />

contain. A warning will be shown on entering the zone programming indicating that<br />

the zone is only able to be viewed and the records are locked.<br />

When selecting a Zone or Trouble Zone the zone address is entered using the Module Type,<br />

Module Address and the number of the zone or trouble zone, this is called Protégé Object<br />

Notation. Information on the Protégé Object Notation and how it applies to programmable<br />

objects within the Protégé System refer to the Object Notation Section on Page 402.<br />

For the alarm memory to display a trouble zone when a tamper/short occurs, the 24hr<br />

processing must be enabled for at least one of the area's that the zone has been assigned in.<br />

To access the Zone programming menu login using a valid installer code and then select<br />

[MENU, 4, 2, 1]. The screen displays “Select zone to modify” as shown in the following<br />

example.<br />

Select zone to<br />

modify: CP001:01<br />

121 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>