For UL and cUL listed installations you MUST set the polling time to 180 seconds or<br />

less.<br />

Analog Expander Module Options<br />

Options that relate to the Analog expander module can be set using option entry.<br />

AE001 Module<br />

[--------]<br />

To modify the module options, use the keypad as explained in section Entering Data Options<br />

on Page 409.<br />

Option 1 – Invert Module Tamper<br />

Enabled the analog expander will invert the module tamper input allowing a<br />

normally open (door closed) tamper switch to be used.<br />

Disabled the analog expander will use the standard normally closed (door<br />

closed) tamper switch.<br />

Option 2 – Virtual Module<br />

Enabled a physical module can’t register at this address. This is used to<br />

protect Zones, PGM’s etc that are used by functions.<br />

Disabled modules can register as normal.<br />

Option 3, 4, 5, 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Analog Expander Channel 1 Options<br />

The channel one options configures the first channel on the Analog Expander. Please not that<br />

the settings may not relate to the particular device connected. Some options relate to the<br />

<strong>PRT</strong>-DAC4 Analog Output Expander and others to <strong>PRT</strong>-ADC4 Analog Input Expander.<br />

The channel options require a module init or module init with reboot to take affect<br />

with the exception of the Log Channel Data Option 7, which is a controller based<br />

configuration setting.<br />

AE001 Ch 1 Opts<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 – Enable Channel Operation<br />

Enabled the analog expansion device will process messages according to the<br />

options configuration and module type.<br />

Disabled the channel will perform no function.<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />