Enabled the PX16 will activate the relays when they go offline.<br />

Disabled the PX16’s will deactivate the relays when they go offline.<br />

Option 4 - 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

Reader Port 2 Function PGM<br />

You can assign a PGM or PGM group that is used by the multiple badge options.<br />

RD001 R2 Func<br />

pgm: --000:00<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and<br />

PGM Groups on Page 410.<br />

Reader Communication Failure Card Reading Operation<br />

When the reader expander fails to communicate with the system controller it will default to<br />

allowing access through the controlled doors based on the offline communication failure<br />

configuration and the type of module that has been registered at the reader location. An<br />

intelligent reader expander device will always process users based on the internal offline<br />

database and the configuration settings have no affect unless the No Cards option is selected.<br />

RD001 Offline<br />

All Cards<br />

Option<br />

No Cards<br />

All Cards<br />

First Ten<br />

Site Code<br />

Function<br />

Setting no cards will prevent ANY access from a card reader in the event<br />

the module fails and goes offline. This is also applicable to the <strong>PRT</strong>-RDI2<br />

and <strong>PRT</strong>-RDE2 modules.<br />

This will allow ANY card to enter a reader on the <strong>PRT</strong>-RDM2 and <strong>PRT</strong>-<br />

RDS2 however on the <strong>PRT</strong>-RDI2 and <strong>PRT</strong>-RDE2 only cards that have the<br />

correct access credentials according to the internal database at the<br />

module will be allowed access.<br />

This will allow UN00001 to UN00010 to have unlimited access to the<br />

reader inputs on the <strong>PRT</strong>-RDM2 and <strong>PRT</strong>-RDS2 however on the <strong>PRT</strong>-<br />

RDI2 and <strong>PRT</strong>-RDE2 only cards that have the correct access credentials<br />

according to the internal database at the module will be allowed access.<br />

During the operation of the <strong>PRT</strong>-RDM2 and <strong>PRT</strong>-RDS2 the application<br />

will store the site codes of cards that have been granted access to the<br />

door, the site code will be cached for a period of 7 days or until the card<br />

is denied access normally. Setting this option will allow ANY card with<br />

the same site code to access the readers on the <strong>PRT</strong>-RDM2 and <strong>PRT</strong>-<br />

RDI2 modules. The <strong>PRT</strong>-RDI2 and <strong>PRT</strong>-RDE2 only cards that have the<br />

correct access credentials according to the internal database at the<br />

module will be allowed access.<br />

Use the [1] and [3] keys to scroll the available offline communication settings. For more<br />

information about the list control data entry refer to the section List Control Data Entry on<br />

Page 406.<br />

115 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>