Option 2 – Disable Red LED Processing<br />

Enabled the reader expander will not control the Red LED (L2) and the PGM<br />

can be used for another function, this is particularly useful if the attached<br />

proximity reader LED’s is controlled with one wire.<br />

Disabled the reader will turn on the Red LED when the door is locked.<br />

Option 3 – Disable Green LED Processing<br />

Enabled the reader expander will not control the Green LED (L1) and the<br />

PGM can be used for another function, this is particularly useful if the<br />

attached proximity reader LED’s is controlled with one wire.<br />

Disabled the reader will turn on the Green LED when the door is unlocked.<br />

Option 4 – Disable Buzzer Processing<br />

Enabled the reader expander will not control the Buzzer Output (BZ) and<br />

the PGM can be used for another function.<br />

Disabled the reader will control the buzzer output.<br />

Option 5 - 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

Reader Port 2 Elevator Options<br />

Options that relate to the elevator functions.<br />

RD001 R2 Elv Opt<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 – Invert Floor Relays<br />

Enabled the reader expander will invert all the relays on the PX16’s<br />

connected that are used for elevator control.<br />

Disabled the reader will not invert the relays.<br />

Option 2 – Control on Comm Fail<br />

Enabled the PX16 used for elevator control will control the state of the<br />

relays when they go offline. Option 3 determines the state the relays will<br />

go into.<br />

Disabled the PX16 used for elevator control will not change the state of the<br />

relays when they go offline..<br />

Option 3 – Activate on Comm Fail<br />