01.07.2014 Views

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Use the [1] and [3] keys to scroll the available reader type settings. For more information<br />

about the list control data entry refer to the section List Control Data Entry on Page 406.<br />

Arming Mode<br />

ENTRY Reader<br />

EXIT Reader<br />

Operation<br />

The reader is located on the outside of the door and is used<br />

to enter in to the area that is being protected by the door.<br />

This is the default setting and should be set for all general<br />

access doors (single reader)<br />

The reader is located on the inside of the door and is used<br />

to exit out of the area that is being protected by the door.<br />

If the reader expander is configured for multiplex<br />

reader mode the multiplexed reader is ALWAYS the<br />

EXIT reader.<br />

Reader Port 2 Keypad Operation Mode<br />

The keypad operation mode programmed for the reader on port two determines if the reader<br />

port has a pin entry device attached or uses a local LCD keypad.<br />

RD001 R2 Key Mod<br />

None<br />

Use the [1] and [3] keys to scroll the available keypad mode settings. For more information<br />

about the list control data entry refer to the section List Control Data Entry on Page 406.<br />

When a Wiegand 26 Bit Keypad is used PIN numbers that are prefixed with a 0 can<br />

not be used and the maximum pin number is limited to 65533. This is a limitation of<br />

the 26 Bit Format and not the Reader Expander. To utilize the full 8 digit capacity for<br />

the PIN number of a user and allow prefixed PIN numbers select a PIN device that<br />

supports the ARK-501 or 4 Bit Output Formats.<br />

Reader Port 2 LCD Keypad<br />

If the keypad operation mode is set to use one of the selected LCD keypads you can program<br />

the address of the keypad to use for pin entry. When using this mode of operation the LCD<br />

keypad will present a login message when a valid card is presented that requires pin entry.<br />

RD001 R2 Keypad<br />

None<br />

Use the [1] and [3] keys to scroll the available keypad mode settings. For more information<br />

about the list control data entry refer to the section List Control Data Entry on Page 406.<br />

Reader Port 2 Multi Badge Operation<br />

The reader port can perform various operations when a user badges their card multiple times.<br />

The list below details the modes this can operate in.<br />

When a multi badge operation has taken place the reader expander will beep the buzzer<br />

output four times. In area control, if the area is already armed the reader will only beep<br />

twice.<br />

RD001 R2 Badge<br />

None<br />