Disabled the reader will not perform any user area functions.<br />

Option 4 - Generate Reader Events<br />

Enabled the reader events will be logged to the event review log.<br />

Disabled the reader will not log the events to the event review log.<br />

Option 5 - Swap LED Lock Display<br />

Enabled the LED display associated with the lock status will follow lock<br />

output two. Use this option when a reader expander is used in an ENTRY<br />

and EXIT configuration and only one lock output is controlling the door.<br />

Disabled the lock and LED display is processed normally.<br />

Option 6 - Activate Access Level PGM<br />

Enabled the reader expander will activate the PGM assigned to the users<br />

access level that gained access to the door or reader.<br />

The user must have the allow access level PGM option enabled.<br />

Disabled the reader will not perform any action on the access level PGM.<br />

Option 7 - Display Card Data<br />

Enabled the reader expander will display the actual card data received from<br />

the reader when the card number is not known. This can be used to<br />

interface with custom third party applications that require their own<br />

processing of card information. This option is enabled by default and can be<br />

used to add card data to a user when operating the Protégé System<br />

Management Suite Application.<br />

Disabled the reader will display the card number not found message.<br />

Option 8 - Arm User Area<br />

Enabled the reader will arm the user's area when they perform a dual<br />

presentation of their card to the associated reader. The users area must still<br />

be available in the user area group assigned to the users access level for<br />

this to correctly operate.<br />

Disabled the reader will not perform any user area arming functions.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Reader Port 1 Extra Options<br />

Options that relate to the extra reader functions.<br />

RD001 R1 Extra<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />