01.07.2014 Views

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Disabled the reader will silently discard any format error. The format error<br />

will still be indicated on the reader input data LED.<br />

Option 8 - Intelligent Reader Tamper<br />

Enabled the reader expander will assume that the external device has smart<br />

messaging that allows a communication path to be formed from the reading<br />

device (Card Reader) to the reader expander.<br />

This allows the reader expander to monitor the reading device and<br />

generate a reader missing alarm (Trouble Zone) if it fails to<br />

communicate with the reader expander allowing the failure to be<br />

reported to a monitoring station. For more information refer to the<br />

Nano Prox Programming <strong>Manual</strong>.<br />

Disabled the intelligent reader mode is disabled.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Reader Port 1 Miscellaneous Options<br />

Options that relate to the miscellaneous reader functions.<br />

RD001 R1 Misc<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Disarm Area<br />

Enabled the reader process will disarm the area designated by the reader<br />

type (ENTRY or EXIT) and the door configuration programmed (If it has an<br />

area on the inside or outside assigned).<br />

If this option is enabled and the reader is only used for area control then<br />

the area disarmed will be the area assigned in the area control setting.<br />

Disabled the reader will not perform any disarm functions.<br />

Option 2 - Allow User Access if Area Armed<br />

When the option is enabled the user will be granted access based on the<br />

access control configuration only and the area status will not be checked<br />

against the user’s ability to disarm the area.<br />

When the option is disabled and the user who is attempting access to a door<br />

that has an area assigned that is armed and the user can not disarm the<br />

area the user will be denied entry to the door even though they may have<br />

the correct door and schedule settings.<br />

Option 3 - Disarm User Area<br />

Enabled the reader will disarm the user's area when access is granted to the<br />

door they are attempting to access. The users area must still be available in<br />

the user area group assigned to the users access level.<br />

101 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>