The reader port can perform various operations when a user badges their card multiple times.<br />

The list below details the modes this can operate in.<br />

When a multi badge operation has taken place the reader expander will beep the buzzer<br />

output four times. In area control, if the area is already armed the reader will only beep<br />

twice.<br />

RD001 Arming<br />

Arm on 2 Reads<br />

Use the [1] and [3] keys to scroll the available arming operation settings. For more<br />

information about the list control data entry refer to the section List Control Data Entry on<br />

Page 406.<br />

Mode<br />

None<br />

Arm on 2 Reads<br />

Arm on Card Read and<br />

Zone Input 4<br />

Arm on 3 Reads<br />

Toggle Function PGM<br />

Activate Function PGM<br />

Operation<br />

No action will be taken by the system for arming an area<br />

associated with the door.<br />

Two successive reads from the same user will result in the<br />

inside or outside area (depending on the card reader type<br />

configuration) starting the arming process.<br />

Pressing and holding Zone Input 4 (RDXXX:04) while<br />

presenting a card will begin arming. Zone 4 must be in an<br />

area that is armed to ensure the zone information is<br />

transmitted to the system controller. The area armed will<br />

depend on the card reader type setting.<br />

This option can not be used with the <strong>PRT</strong>-<br />

RDM2, Zone 4 is not available on the module.<br />

Use another arming method or use the <strong>PRT</strong>-<br />

RDS2 or <strong>PRT</strong>-RDI2.<br />

Three successive reads from the same user will result in the<br />

inside or outside area (depending on the card reader type<br />

configuration) starting the arming process.<br />

Three successive reads from the same user will result in the<br />

function PGM state being toggled. If the PGM is currently<br />

on it will be turned off and if it is off it will be turned on.<br />

Three successive reads from the same user will result in the<br />

function PGM state being turned on<br />

Reader Port 1 Reader Options<br />

Options that directly relate to the control of reader functions.<br />

RD001 R1 Option<br />

[123-5---]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Reader On Unlock and Door Open<br />

Enabled the reader expander will send card information to the system<br />

controller when a door is unlocked or opened. This option is set by default<br />

and should be left set if the door controls areas or time and attendance<br />

events are required from the reader port<br />

99 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>