64 <strong>Barracuda</strong> <strong>18LP</strong> Product Manual, Rev. E<br />

Notes [ ] for Tables 13b and 13d.<br />

[1] See Section 9.7.1 for detailed electrical characteristics of these signals.<br />

[2] The conductor number refers to the conductor position when using 0.025-inch (0.635 mm) centerline flat<br />

ribbon cable. Other cables types may be used to implement equivalent contact assignments.<br />

[3] Connector contacts are on 0.050 inch (1.27 mm) centers.<br />

[4] Front panel LED signal; indicates drive activity for host front panel hard drive activity indicator.<br />

[5] Asserted by host to enable Motor Start option (enables starting motor via SCSI bus command).<br />

[6] Asserted by host to enable Delayed Motor Start option (motor starts at power on or after a delay of 12 seconds<br />

times drive ID). This and [5] above are mutually exclusive options.<br />

[7] Binary code on A3, A2, A1 and A0 asserted by host to set up SCSI bus ID in drive.<br />

[8] GND provides a means for differential devices to detect the presence of a single ended device on the bus.<br />

Drive will not operate I/O bus at ULTRA-2 data rates if this is grounded.<br />

[9] Signals [4] through [7] are used in place of installing jumpers and cables on option select connectors J2<br />

and J6. See Section 8.1.1 notes.<br />

[10] “NC” means no connection.<br />

[11] 8 bit devices which are connected to the 16 data bit differential I/O shall leave the following signals open:<br />

–DB12 –DB13 –DB14 –DB15 –DBP1 –DB8 –DB9 –DB10 –DB11,<br />

+DB12 +DB13 +DB14 +DB15 +DBP1 +DB8 +DB9 +DB10 +DB11.<br />

8 bit devices which are connected to the 16 data bit single-ended I/O shall have the following signals connected<br />

as shown:<br />

to ground: +DB12 +DB13 +DB14 +DB15 +DBP1 +DB8 +DB9 +DB10 +DB11,<br />

open circuit: –DB12 –DB13 –DB14 –DB15 –DBP1 –DB8 –DB9 –DB10 –DB11.<br />

All other signals should be connected as shown.