<strong>Barracuda</strong> <strong>18LP</strong> Product Manual, Rev. E 45<br />
Table 7 lists the Standard Inquiry command data that the drive should return to the initiator per the format given<br />
in the SCSI Interface Product Manual, part number 77738479, Inquiry command section.<br />
Table 7:<br />
Bytes<br />
<strong>Barracuda</strong> <strong>18LP</strong> family drive Standard Inquiry data<br />
Data (HEX)<br />
0-15 00 00 [02] 1 [12] 2 8B 00 01 3E 53 45 41 47 41 54 45 20 VENDOR ID<br />
16-31 53 54 [33] [39] [31] [37] [35] [4C] 3 [43] 3 [20] 3 20 20 20 20 20 20 PRODUCT ID<br />
32-47 R# R# R# R# S# S# S# S# S# S# S# S# 00 00 00 00<br />
48-63 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />
64-79 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />
80-95 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00<br />
96-111 00 43 6F 70 79 72 69 67 68 74 20 28 63 29 20 [31] COPYRIGHT<br />
112-127 [39] [39] [38] 4 20 53 65 61 67 61 74 65 20 41 6C 6C 20 NOTICE<br />
128-143 72 69 67 68 74 73 20 72 65 73 65 72 76 65 64 20<br />
[] 1 01 means SCSI-1 implemented;<br />
02 means SCSI-2/SCSI-3 implemented. Default is 02.<br />
[] 2 01 means response data in SCSI-1 format and has compatibility with Common Command Set data.<br />
02 means response data in SCSI-2/SCSI-3 format. In addition, 12 indicates that the drive uses the hierarchial<br />
addressing mode to assign LUNs to logical units. Default is 12.<br />
R# Four ASCII digits representing the product Firmware Version number. The Firmware Release Number is<br />
also given in the Vital Product Data page C0h, together with servo RAM and ROM release numbers.<br />
S# Eight ASCII digits representing the eight digits of the product serial number.<br />
[] 3 Bytes 18 through 25 reflect model of drive. Shown here are hex values for Model ST39175<strong>LC</strong>. Other possible<br />
values for the various models are listed below.<br />
<strong>ST39175LW</strong> 33 39 31 37 35 4C 57 20<br />
ST318275<strong>LC</strong> 33 31 38 32 37 35 4C 43<br />
<strong>ST318275LW</strong> 33 31 38 32 37 35 4C 57<br />
[] 4 Copyright Year - changes with actual year.<br />
9.3.1 Inquiry Vital Product data<br />
Instead of the standard Inquiry data shown in Table 7, the initiator can request several Vital Product Data<br />
pages by setting the Inquiry command EVPD bit to one. The SCSI Interface Product Manual, part number<br />
77738479, lists the Vital Product Data pages and describes their formats. A separate Inquiry command must<br />
be sent to the drive for each Vital Product Data page the initiator wants the drive to send back.<br />
Table 8 shows the Vital Product Data pages for the drives of this product manual. “Y” means reporting that particular<br />
parameter is supported, but it may be different for each drive.