<strong>Barracuda</strong> <strong>18LP</strong> Product Manual, Rev. E 37<br />

8.1.1 Function description<br />

J2<br />

jumper<br />

installation<br />

SE<br />

On<br />

Off<br />

Jumper function description<br />

Forces drive to use single-ended I/O drivers/receivers only.<br />

Drive can operate on the interface in low voltage differential mode or single-ended,<br />

depending on the voltage state of the I/O “DIFFSNS” line. Default is no jumper on.<br />

DS ME<br />

Off Off Spindle starts immediately after power up—Default setting.<br />

Off On Drive spindle does not start until Start Unit command received from host.<br />

On Off Spindle Startup is delayed by SCSI ID times 12 seconds after power is applied, i.e., drive 0<br />

spindle starts immediately when DC power connected, drive 1 starts after 12 second delay,<br />

drive 2 starts after 24 second delay, etc.<br />

On On Drive spindle starts when Start Unit command received from host. Delayed start feature is<br />

overridden and does not apply when ME jumper is installed.<br />

WP<br />

On<br />

Off<br />

PD<br />

On<br />

Off<br />

RES (2)<br />

Off<br />

Entire drive is write protected.<br />

Drive is not write protected. Default is no WP jumper installed.<br />

Parity checking and parity error reporting by the drive is disabled.<br />

Drive checks for parity and reports result of parity checking to host.<br />

Default is PD jumper not installed.<br />

Reserved jumper position. Default is no jumper installed.<br />

TP (“LW” model only)<br />

Off<br />

No terminator power is connected to drive terminators or SCSI bus I/O cable.* No jumpers<br />

on is factory default.<br />

On<br />

Drive supplies power to SCSI bus I/O cable.* A jumper on the TP position may be needed to<br />

power external terminators (see Section 9.8 and Figure 10).<br />

*See Figure 7c for pins used for Termpower.<br />

8.2 Drive orientation<br />

The balanced rotary arm actuator design of the drive allows it to be mounted in any orientation. All drive performance<br />

characterization, however, has been done with the drive in horizontal (discs level) and vertical (drive on<br />

its side) orientations, and these are the two preferred mounting orientations.<br />

8.3 Cooling<br />

Cabinet cooling must be designed by the customer so that the ambient temperature immediately surrounding<br />

the drive will not exceed temperature conditions specified in Section 6.4.1, “Temperature.” Specific consideration<br />

should be given to make sure adequate air circulation is present around the printed circuit board (PCBA)<br />

to meet the requirements of Section 6.4.1, “Temperature.”<br />

8.3.1 Air flow<br />

The rack, cabinet, or drawer environment for the <strong>Barracuda</strong> <strong>18LP</strong> drive must provide heat removal from the<br />

electronics and head and disc assembly (HDA). You should confirm that adequate heat removal is provided<br />

using the temperature measurement guidelines described in Section 6.4.1.