26 <strong>Barracuda</strong> <strong>18LP</strong> Product Manual, Rev. E<br />

6.4.2 Relative humidity<br />

The values below assume that no condensation on the drive occurs.<br />

a. Operating<br />

5% to 95% non-condensing relative humidity with a maximum gradient of 10% per hour.<br />

b. Non-operating<br />

5% to 95% non-condensing relative humidity.<br />

6.4.3 Effective altitude (sea level)<br />

a. Operating<br />

–1,000 to +10,000 feet (–305 to +3,048 meters)<br />

b. Non-operating<br />

–1,000 to +40,000 feet (–305 to +12,210 meters)<br />

6.4.4 Shock and vibration<br />

Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is<br />

installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur<br />

internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent,<br />

it may be necessary to modify the enclosure to minimize drive movement.<br />

The limits of shock and vibration defined within this document are specified with the drive mounted by any of<br />

the four methods shown in Figure 5, and in accordance with the restrictions of Section 8.4. Orientation of the<br />

side nearest the LED may be up or down.<br />

6.4.4.1 Shock<br />

a. Operating—normal<br />

The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not<br />

exceeding 5 Gs at a maximum duration of 11 msec (half sinewave). Shock may be applied in the X, Y, or Z<br />

axis.<br />

b. Operating—abnormal<br />

Equipment, as installed for normal operation, does not incur physical damage while subjected to intermittent<br />

shock not exceeding 10 Gs at a maximum duration of 11 msec (half sinewave). Shock occurring at<br />

abnormal levels may promote degraded operational performance during the abnormal shock period. Specified<br />

operational performance will continue when normal operating shock levels resume. Shock may be<br />

applied in the X, Y, or Z axis. Shock is not to be repeated more than two times per second.<br />

c. Non-operating<br />

The limits of non-operating shock shall apply to all conditions of handling and transportation. This includes<br />

both isolated drives and integrated drives.<br />

The drive subjected to nonrepetitive shock not exceeding 75 Gs at a maximum duration of 11 msec (half<br />

sinewave) shall not exhibit device damage or performance degradation. Shock may be applied in the X, Y,<br />

or Z axis.<br />

The drive subjected to nonrepetitive shock not exceeding 150 Gs at a maximum duration of 2 msec (half<br />

sinewave) does not exhibit device damage or performance degradation. Shock may be applied in the X, Y,<br />

or Z axis.