THE ULTIMATE SURGICAL TOOL - Quanta System
THE ULTIMATE SURGICAL TOOL - Quanta System THE ULTIMATE SURGICAL TOOL - Quanta System
THE Cyber TM 150 SURGERY MEDICAL DIVISION THULIUM SURGICAL LASER SYSTEM THE ULTIMATE SURGICAL TOOL FOR BPH AND BEYOND SPEED > POWER > VERSATILITY
- Page 2 and 3: THULIUM SURGICAL LASER SYSTEM 150 W
- Page 4: The Q1 Imprinting Q1 DNA is the phi
<strong>THE</strong> Cyber TM 150<br />
SURGERY<br />
MEDICAL DIVISION<br />
THULIUM <strong>SURGICAL</strong> LASER SYSTEM<br />
<strong>THE</strong><br />
<strong>ULTIMATE</strong><br />
<strong>SURGICAL</strong><br />
<strong>TOOL</strong><br />
FOR BPH<br />
AND BEYOND<br />
SPEED > POWER > VERSATILITY
THULIUM <strong>SURGICAL</strong> LASER SYSTEM 150 W<br />
UNMATCHED SPEED<br />
Since 2-micron laser wavelength is<br />
strongly absorbed by water which is<br />
ubiquitous in all tissues, the speed<br />
of cutting and vaporizing will remain<br />
relatively constant regardless of tissue<br />
vascularization.<br />
Energy from the Cyber TM 150<br />
penetrates only fraction of millimetre<br />
in the tissue ,providing the surgeon<br />
with a high degree of control and<br />
reducing substantially the risk of<br />
inadvertent injury.<br />
SUPERIOR PRECISION<br />
For cutting and vaporizing speed the<br />
powerful Cyber TM 150 has no rival.<br />
Compared with holmium lasers, the<br />
Cyber TM 150 wavelength is more<br />
efficiently absorbed by wather,<br />
reducing the vaporization time. Due<br />
to the cutting characteristics and<br />
available laser fibers that the Cyber<br />
TM offers, the surgeon has the option<br />
of vaporization, vaporesection or<br />
vapoenucleation which allows for the<br />
selection of the optimal approach.<br />
Only the Cyber TM 150 does it all.<br />
UROLOGIC APPLICATIONS:<br />
• BPH<br />
•<br />
• enucleation<br />
• resection<br />
• vaporization<br />
Excision of tumors<br />
Bladder Neck Incision<br />
Partial Nephrectomy<br />
(without clamping of the renal artery)<br />
MULTIDISCIPLINARY<br />
APPLICATIONS:<br />
Thoracic Surgery<br />
ENT<br />
• Gynecology<br />
General Surgery<br />
This 150 W<br />
Cyber TM 150 Thulium Laser<br />
provides the ideal blend of high<br />
efficiency cutting and effective<br />
coagulating effects, making it the<br />
most ideal prostate laser instrument<br />
available.<br />
Deeper coagulation may be a key<br />
factor influencing increased dysuria<br />
rates and other post-procedural<br />
complications. Thulium laser has<br />
the lowest value of coagulation<br />
depth (0.1-0.2 mm) providing great<br />
haemostatic effects and extremely<br />
confined thermal issues.<br />
Features for Patients and Doctors:<br />
• Shorter Hospital Stay<br />
• Minimal post-operative<br />
catheterization time<br />
• Quick return to the normal activity<br />
with minimal recovery time.<br />
• Minimal blood losses<br />
• Treatments on patients under<br />
anticoagulant<br />
• Preserving the integrity of endoscopes<br />
and instruments<br />
• Reusable and single use fibres<br />
• Neutral colour of safety glasses<br />
• Multidisciplinary <strong>System</strong> for minimally<br />
invasive surgeries<br />
Ultra Fast and Efficient BPH Technique<br />
VAPORIZATION<br />
RESECTION<br />
ENUCLEATION<br />
Select your technique with Cyber TM 150 W!<br />
Now you can choose the correct surgical procedure for<br />
each prostate dimension and morphology.<br />
Use the Cyber TM in open surgery taking advantage<br />
of its exceptional simultaneus effects of ablation and<br />
coagulation!
SURGERY<br />
MEDICAL DIVISION<br />
Cyber TM 150<br />
TECHNICAL SPECIFICATIONS<br />
Wavelength<br />
2010 nm<br />
Laser Class 4 (IEC/EN 60825-1:2007)<br />
Power<br />
Up to 150W depending on each local clearance<br />
Power setting<br />
1W to 150W in 1, 2, 5 W increment steps<br />
Treatment mode<br />
Continuous wave or pulsed (25-50-75 ns)<br />
Beam delivery<br />
Wide range of flexible silica frontal and side-firing fibers<br />
Aiming beam<br />
Red (650nm) adjustable
The Q1 Imprinting<br />
Q1 DNA is the philosophy that<br />
characterises <strong>Quanta</strong> <strong>System</strong> products.<br />
Each machine is the perfect synthesis<br />
(100% Q1) of Human Intelligence<br />
and technological know-how, two<br />
factors that make the development of<br />
innovative laser technologies a natural<br />
process at <strong>Quanta</strong> <strong>System</strong>.<br />
Innovative Philosophy<br />
<strong>Quanta</strong> <strong>System</strong> produces lasers<br />
and laser systems for a wide range<br />
of scientific, medical and industrial<br />
applications. DNA Laser Technology is<br />
not just a marketing promise, It Is also a<br />
way of thinking, working, and creating<br />
values to be shared, it is a concrete and<br />
profound commitment, the corporate<br />
policy of an expert and determined<br />
group which makes technological<br />
research its mission every day.<br />
D N A L A S E R T E C H N O L O G Y<br />
OUTSTANDING SAFETY<br />
Many of the risks associated with other laser<br />
wavelengths are minimized or avoided with the Cyber TM 150.<br />
Safety features include:<br />
• Clear surgical field free of blood, bubbles and debris.<br />
• Observable surgical effect – “what you see is what you get” – no unseen deep tissue effects occur.<br />
• Forward-firing laser fibers combined with high water absorption results in reduced chance of inadvertent tissue damage.<br />
• Minimal bleeding<br />
QTS-CYBERTM 150 -rev004 USA<br />
Clear Surgical Field<br />
The consistent power delivery of the Cyber TM 150’s continuous wave mode creates even and clean vaporization or cutting<br />
effect which keeps the surgical field clear of bubbles, blood or debris that can impair the surgeon’s vision.<br />
No Unseen Effects<br />
The 2-micron wavelength of the Cyber TM 150 is readily absorbed in water. Therefore the affect the surgeon sees is the only<br />
affect being created. Other wavelengths penetrate more deeply in tissue giving rise to the potential for unwanted affects such<br />
as edema and delayed healing.<br />
Energy Delivered Where You Want It<br />
The forward-firing fiber of the Cyber TM provides added protection from inadvertent misdirected laser light. In addition, the<br />
high water absorption characteristics of the 2-micron wavelength avoids the possibility of laser light traveling through the<br />
aqueous surgical field to tissues not intended for treatment.<br />
True Colors with No Glare<br />
Since clear safety lenses can be used with the Cyber TM 150, there is no impairment of the surgeon’s vision due to color<br />
distortion and the invisible infrared laser light produces no glare.<br />
The information provided about clinical applications represent a general overview for the described products.<br />
National health care regulations vary between countries and may exclude certan clinical applications at your location.<br />
The user assumes responsibility to be updated about national deviations from the listed applications.<br />
For the USA market, please browse the related 510(K) n. K102749<br />
<strong>Quanta</strong> <strong>System</strong> S.p.A<br />
Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy<br />
Tel. +39 0331.376797 - Fax +39-0331.367815<br />
quanta@quantasystem.com<br />
www.quantasystem.com