Vulkan Lokring MGLD.3000 Product Manual - Schoonover, Inc.
Vulkan Lokring MGLD.3000 Product Manual - Schoonover, Inc. Vulkan Lokring MGLD.3000 Product Manual - Schoonover, Inc.
Multi Gas Leak Detector MGLD.3000 Operating instructions 3.3.3. Probes for the MGLD.3000 Product number L14004006 L14004007 L14004008 Product description LOKtool Refrigerant Probe LOKtool Tracergas Probe LOKtool CO2-R744 Probe Labeling on the housing REFRIGERANT TRACERGAS / H2 CO2 Detectable gases R22, R134a, R290, R404A, R407C, R410A*, R600a* Lower detection threshold value 10 ppm, 0.3 g/year 1 ppm 100 ppm, 5 g/year *0.1 g/year Response time < 1 sec < 1 sec < 2 sec Dimensions (probe without flexible sensor extension) approx. 192 mm x 40 mm x 28 mm approx. 192 mm x 40 mm x 28 mm approx. 180 mm x 54 mm x 28 mm Dimensions (probe with flexible sensor extension) approx. 522 mm x 40 mm x 28 mm approx. 522 mm x 40 mm x 28 mm approx. 510 mm x 54 mm x 28 mm Dimensions (probe with flexible approx. 295 g approx. 295 g approx. 410 g sensor extension) Length of connection line approx. 6 m Net weight of connection line approx. 430 g Permissible operating temperature 0 °C – +55 °C Permissible operating humidity 20... 80 % rel. hum. Permissible storage temperature -25 °C – +70 °C Permissible storage humidity 20... 80 % rel. hum. Permissible storage conditions The storage area and environment must be free of any impurities and contaminants, and in particular must be protected from the influence of chemical substances, e.g. silicone. H 2 R744 BAL_MGLD3000_20101001_en.doc 16-54
Multi Gas Leak Detector MGLD.3000 Operating instructions 4. Installation and commissioning Caution! Follow the safety instructions provided in chapter 2. 4.1. Unpacking device from packing materials When unpacking the device, examine the device and compare it with the packing list to make sure that all parts are included and undamaged. Do not discard the transport packaging. In the event that the materials need to be returned, they will need to be returned in the original packaging. Only in this way can the returned materials be protected from damage during transport. 4.2. Installation and commissioning the MGLD.3000 4.2.1. Stationary operation of the device with docking unit/charging batteries on the base unit Caution! Exercise caution during device assembly and setup to prevent injury to hands and fingers! Place the docking unit on its feet in the designated location. A level, dry, secure, and stable surface is required. Make sure the docking unit is placed on a level and stable surface where it cannot slip or wobble. Connect the included power connection cord to the docking unit power connection. Caution! Observe the layout of both devices (front side by front side)! There must be no foreign objects between the docking unit and the base unit BAL_MGLD3000_20101001_en.doc 17-54
- Page 1 and 2: MGLD.3000 OPERATING INSTRUCTIONS 01
- Page 3 and 4: Multi Gas Leak Detector MGLD.3000 O
- Page 5 and 6: Multi Gas Leak Detector MGLD.3000 O
- Page 7 and 8: Multi Gas Leak Detector MGLD.3000 O
- Page 9 and 10: Multi Gas Leak Detector MGLD.3000 O
- Page 11 and 12: Multi Gas Leak Detector MGLD.3000 O
- Page 13 and 14: Multi Gas Leak Detector MGLD.3000 O
- Page 15: Multi Gas Leak Detector MGLD.3000 O
- Page 19 and 20: Multi Gas Leak Detector MGLD.3000 O
- Page 21 and 22: Multi Gas Leak Detector MGLD.3000 O
- Page 23 and 24: Multi Gas Leak Detector MGLD.3000 O
- Page 25 and 26: Multi Gas Leak Detector MGLD.3000 O
- Page 27 and 28: Multi Gas Leak Detector MGLD.3000 O
- Page 29 and 30: Multi Gas Leak Detector MGLD.3000 O
- Page 31 and 32: Multi Gas Leak Detector MGLD.3000 O
- Page 33 and 34: Multi Gas Leak Detector MGLD.3000 O
- Page 35 and 36: Multi Gas Leak Detector MGLD.3000 O
- Page 37 and 38: Multi Gas Leak Detector MGLD.3000 O
- Page 39 and 40: Multi Gas Leak Detector MGLD.3000 O
- Page 41 and 42: Multi Gas Leak Detector MGLD.3000 O
- Page 43 and 44: Multi Gas Leak Detector MGLD.3000 O
- Page 45 and 46: Multi Gas Leak Detector MGLD.3000 O
- Page 47 and 48: Multi Gas Leak Detector MGLD.3000 O
- Page 49 and 50: Multi Gas Leak Detector MGLD.3000 O
- Page 51 and 52: Multi Gas Leak Detector MGLD.3000 O
- Page 53 and 54: Multi Gas Leak Detector MGLD.3000 O
- Page 55: Multi Gas Leak Detector MGLD.3000 O
Multi Gas Leak Detector <strong>MGLD.3000</strong><br />
Operating instructions<br />
3.3.3. Probes for the <strong>MGLD.3000</strong><br />
<strong>Product</strong> number L14004006 L14004007 L14004008<br />
<strong>Product</strong> description<br />
LOKtool Refrigerant<br />
Probe<br />
LOKtool Tracergas Probe LOKtool CO2-R744<br />
Probe<br />
Labeling on the housing<br />
REFRIGERANT TRACERGAS / H2 CO2<br />
Detectable gases R22, R134a, R290,<br />
R404A, R407C, R410A*,<br />
R600a*<br />
Lower detection threshold value 10 ppm, 0.3 g/year 1 ppm 100 ppm, 5 g/year<br />
*0.1 g/year<br />
Response time < 1 sec < 1 sec < 2 sec<br />
Dimensions (probe without flexible<br />
sensor extension)<br />
approx. 192 mm x 40<br />
mm x 28 mm<br />
approx. 192 mm x 40 mm<br />
x 28 mm<br />
approx. 180 mm x 54<br />
mm x 28 mm<br />
Dimensions (probe with flexible<br />
sensor extension)<br />
approx. 522 mm x 40<br />
mm x 28 mm<br />
approx. 522 mm x 40 mm<br />
x 28 mm<br />
approx. 510 mm x 54<br />
mm x 28 mm<br />
Dimensions (probe with flexible approx. 295 g approx. 295 g approx. 410 g<br />
sensor extension)<br />
Length of connection line approx. 6 m<br />
Net weight of connection line approx. 430 g<br />
Permissible operating temperature<br />
0 °C – +55 °C<br />
Permissible operating humidity<br />
20... 80 % rel. hum.<br />
Permissible storage temperature -25 °C – +70 °C<br />
Permissible storage humidity<br />
20... 80 % rel. hum.<br />
Permissible storage conditions The storage area and environment must be free of any impurities and contaminants,<br />
and in particular must be protected from the influence of chemical substances,<br />
e.g. silicone.<br />
H 2<br />
R744<br />
BAL_MGLD3000_20101001_en.doc 16-54