CrystalSix Sensor Operating Manual 2.5 CrystalSix Sensor Installation when used with an XTC/2 or XTC/C Follow the instructions of Section 3.5.2 of the XTC/2 - XTC/C Operating Manual (074-183). 2.6 CrystalSix Sensor Installation when used with an IC/4 or IC/4 PLUS 2.6.1 Programming the Relay Outputs 1 From the program menu select Source/Sensor (F4). 2 Select Sensor board 1 or Sensor board 2. 3 Enter the edit mode. (F5) 4 Select Sensor type six (6) for the CrystalSix Sensor. This will enable the CrystalSwitch output. 5 Select a CrystalSwitch output (Relay 1-8 or 1-16) depending upon which I/O board is used. 6 Turn the instrument’s power “OFF”, then “ON”, to ensure that the change takes place permanently. IPN 074-155G 2 - 14
CrystalSix Sensor Operating Manual 2.6.2 Wiring the Relay Outputs with Relay I/O boards 755-122-G1 or 755-122-G1/G2 1 On the relay connector, see Figure 2-7 on page 2-16, connect the leads of the solenoid valve across the one side of a 24 volt supply (see listing) and one side of a relay (1-16 whichever was programmed). Connect a jumper between the second side of the 24 volt supply and the second side of the selected relay. Refer to Figure 2-5 on page 2-10 for a typical installation utilizing relay 1 to perform the crystal advance function for the relay I/O board. Table 2-1 Wiring Connectors (P4) Top Relay Connector (P5) Input Lines Relay Pins Input Pins 1 24, 28 1 1, 20 2 23, 27 2 2, 21 3 22, 26 3 3, 22 4 13, 19 4 4, 23 5 12, 18 5 5, 24 6 11, 17 6 6, 25 7 10, 16 7 7, 26 8 3, 7 8 8, 27 IPN 074-155G (P3) (available on G2 only) Bottom Relay Connector Relay Pins 9 47, 50 9 13, 32 10 14, 17 10 14, 33 11 59, 63 11 15, 34 12 53, 60 12 16, 35 13 34, 36 13 12, 31 14 28, 30 14 11, 30 15 4, 11 15 10, 29 16 1, 5 16 9, 28 Isolated 24 V(dc) source is available with a maximum of 0.4 amps total on connector P4 at Pins 4, 9, 15 and 21 with Pins 8, 14, 20 and 25 used as returns. 2 - 15
- Page 1: O P E R A T I N G M A N U A L CRYST
- Page 4 and 5: Trademarks The trademarks of the pr
- Page 6 and 7: BUSINESS REPLY MAIL FIRST CLASS PER
- Page 9 and 10: CrystalSix Sensor Operating Manual
- Page 11 and 12: 1.1 Specifications for CrystalSix S
- Page 13 and 14: CrystalSix Sensor Operating Manual
- Page 15 and 16: CrystalSix Sensor Operating Manual
- Page 17 and 18: CrystalSix Sensor Operating Manual
- Page 19 and 20: CrystalSix Sensor Operating Manual
- Page 21 and 22: CrystalSix Sensor Operating Manual
- Page 23 and 24: CrystalSix Sensor Operating Manual
- Page 25 and 26: CrystalSix Sensor Operating Manual
- Page 27 and 28: CrystalSix Sensor Operating Manual
- Page 29: CrystalSix Sensor Operating Manual
- Page 33 and 34: CrystalSix Sensor Operating Manual
- Page 35 and 36: CrystalSix Sensor Operating Manual
- Page 37 and 38: 3.3 Electrical and Pneumatic Connec
- Page 39 and 40: CrystalSix Sensor Operating Manual
- Page 41 and 42: CrystalSix Sensor Operating Manual
- Page 43 and 44: CrystalSix Sensor Operating Manual
- Page 45 and 46: CrystalSix Sensor Operating Manual
- Page 47 and 48: CrystalSix Sensor Operating Manual
- Page 49 and 50: CrystalSix Sensor Operating Manual
- Page 51 and 52: CrystalSix Sensor Operating Manual
- Page 53 and 54: 4.6 Replacing the Bellows Assembly
- Page 55 and 56: CrystalSix Sensor Operating Manual
- Page 57 and 58: CrystalSix Sensor Operating Manual
CrystalSix Sensor Operating Manual<br />
2.6.2 Wiring the Relay Outputs with Relay I/O boards<br />
755-122-G1 or 755-122-G1/G2<br />
1 On the relay connector, see Figure 2-7 on page 2-16, connect the leads of<br />
the solenoid valve across the one side of a 24 volt supply (see listing) and<br />
one side of a relay (1-16 whichever was programmed). Connect a jumper<br />
between the second side of the 24 volt supply and the second side of the<br />
selected relay. Refer to Figure 2-5 on page 2-10 for a typical installation<br />
utilizing relay 1 to perform the crystal advance function for the relay I/O<br />
board.<br />
Table 2-1 Wiring Connectors<br />
(P4)<br />
Top Relay Connector<br />
(P5)<br />
Input Lines<br />
Relay Pins Input Pins<br />
1 24, 28 1 1, 20<br />
2 23, 27 2 2, 21<br />
3 22, 26 3 3, 22<br />
4 13, 19 4 4, 23<br />
5 12, 18 5 5, 24<br />
6 11, 17 6 6, 25<br />
7 10, 16 7 7, 26<br />
8 3, 7 8 8, 27<br />
IPN 074-155G<br />
(P3)<br />
(available on G2 only)<br />
Bottom Relay Connector<br />
Relay Pins<br />
9 47, 50 9 13, 32<br />
10 14, 17 10 14, 33<br />
11 59, 63 11 15, 34<br />
12 53, 60 12 16, 35<br />
13 34, 36 13 12, 31<br />
14 28, 30 14 11, 30<br />
15 4, 11 15 10, 29<br />
16 1, 5 16 9, 28<br />
Isolated 24 V(dc) source is available with a maximum of 0.4 amps total on<br />
connector P4 at Pins 4, 9, 15 and 21 with Pins 8, 14, 20 and 25 used as returns.<br />
2 - 15