26.06.2014 Views

PTR 225 / PTR 225 S PTR 237 - Schoonover, Inc.

PTR 225 / PTR 225 S PTR 237 - Schoonover, Inc.

PTR 225 / PTR 225 S PTR 237 - Schoonover, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

High voltage cut-in with positive<br />

logic at Pin 8:<br />

High voltage ON<br />

High voltage OFF<br />

(for this also refer to Fig. 3 and Section 2.2.2).<br />

at U > 12 V<br />

at U < 7 V<br />

1.2.7 Mechanical Data<br />

Dimensions (WxHxD) for<br />

<strong>PTR</strong> <strong>225</strong> / <strong>PTR</strong> <strong>225</strong> S<br />

Weight<br />

80 x 126 x 73 mm<br />

500 g approx.<br />

1.2.6 Status Output<br />

Up to Serial No. D 95 11 01000<br />

Field-effect transistor (FET)<br />

Caution<br />

100 mA max.,<br />

42 V DC max.<br />

When exceeding these maximum ratings,<br />

the <strong>PTR</strong> <strong>225</strong>, <strong>PTR</strong> <strong>225</strong> S, <strong>PTR</strong><br />

<strong>237</strong> itself and / or any connected equipment<br />

may be damaged.<br />

Ready to measure FET conductive (R i<br />

< 100 Ω)<br />

Fault<br />

FET off (R i<br />

> 100 kΩ)<br />

From Serial No. D 95 11 01000<br />

Voltage output which is programmable control compatible<br />

Ready to measure High level (13.5-35 V, max. 50 mA)<br />

Error (not ignited, HV off)<br />

0V<br />

For this refer also to Section 2.2.4.<br />

1.2.8 Ambient Conditions<br />

Storage temperature range -20 °C to +70 °C<br />

Climatic rating KWF to DIN 400 40<br />

Operating temperature range 10 °C to 50 °C<br />

Max. rel. humidity of the ambient air (on 30<br />

days per year, non-condensing) 70 % 1) or 95 % 2)<br />

1) usable measurement range 10 -2 to 10 -7 mbar<br />

2) usable measurement range 10 -2 to 10 -9 mbar<br />

1.3 Technical Description<br />

Based on a supply voltage of 24 V the <strong>PTR</strong> <strong>225</strong>, <strong>PTR</strong><br />

<strong>225</strong> S or <strong>PTR</strong> <strong>237</strong> generates the internal supply voltages<br />

required for operation of the integrated PENNING measurement<br />

system. The <strong>PTR</strong> <strong>225</strong>, <strong>PTR</strong> <strong>225</strong> S or <strong>PTR</strong> <strong>237</strong><br />

supplies a logarithmic representation of the vacuum<br />

pressure by way of a voltage signal which ranges from<br />

6 GA 09.308/4.02 - 05/97<br />