Technical Data Sheet<br />
COMBIFLEX ® -<strong>C2</strong>/S Art.-No. 2 05017<br />
Two component high build bitumen coating<br />
for spray application (to factory specification)<br />
Properties:<br />
• Seamless, jointless, flexible<br />
crack-bridging waterproof<br />
membrane<br />
• Suitable for all conventional<br />
substrates<br />
• Can also be used on matt<br />
damp substrates without<br />
priming<br />
• Quickly rainproof<br />
• Rapid curing<br />
• Simple and efficient application<br />
• Radon barrier<br />
• Cationic emulsified<br />
• Solvent free<br />
• Waterproof material to DIN 18195-2<br />
• Certified for waterproofing of concrete<br />
joints in strips<br />
Areas of application:<br />
COMBIFLEX-<strong>C2</strong>/S is suitable for waterproofing ground<br />
covered building components such as e.g. cellar walls,<br />
foundations, floor slabs or screeds, dependent on the<br />
severity of the wet duty conditions:<br />
• Ground moisture<br />
• Seepage water<br />
• Pressure water<br />
Technical Data:<br />
Basis:<br />
Application/substrate<br />
temperature:<br />
P-2002-4-125/02<br />
bautest Dresden<br />
2 component polymer<br />
modified high build bitumen<br />
coating<br />
+5° C to +35° C<br />
Lower temperatures extend,<br />
higher temperatures reduce<br />
curing times<br />
Reaction time: approx. 10 sec.<br />
Crack bridging: min. 2 mm to DIN 28052-6<br />
Water impermeability: passed to DIN 52123<br />
(slit pressure 1mm)<br />
Material consumption:<br />
• Ground moisture, non-standing seepage water:<br />
4.0 l/m² = approx. 2.5 mm dry film thickness<br />
• Standing seepage water:<br />
6.0 l/m² = approx. 4.0 mm dry film thickness<br />
Greater material consumption for uneven substrates<br />
is not considered.<br />
Packaging:<br />
Storage:<br />
Cleaning materials:<br />
28, 180 and 1000 l<br />
containers<br />
6 months when stored frost<br />
free in the original unopened<br />
containers. Use opened<br />
containers promptly.<br />
Clean tools immediately with<br />
water or AQUAFIN-Cleanser.<br />
Dried on material can only be<br />
removed with difficulty.<br />
Substrate preparation:<br />
The substrate must be frost free, load bearing, flat with<br />
an open-pored texture and have a closed surface.<br />
It must be free from gravel pockets, cavities, gaping<br />
cracks, ridges and be free from adhesion inhibiting<br />
substances such as dust, laitance and loose parts.<br />
Undulations > 5 mm as well as mortar pockets,<br />
rendering grooves in brickwork or dense concrete<br />
blocks, open masonry work joints, voids, substrates with<br />
large pores or uneven masonry work are to be levelled<br />
up beforehand. Corners and edges are to be rounded<br />
or, with concrete sections, to be chamfered post<br />
installation. Mechanically remove laitance at the wall/<br />
floor transition.<br />
Internal corners, wall/floor junctions,<br />
separating joints:<br />
Apply AQUAFIN-RS300 or AQUAFIN-2K/M by brush<br />
or with a 4-6 mm notched trowel to the prepared<br />
substrate at a width 2 cm wider than the joint tape.<br />
Then, without folds or voids, lay the ASO-Joint-Tape-<br />
2000/2000-S into the fresh coat. The joint tape must<br />
be bonded in such a way as to exclude water migration<br />
to the rear of the ASO-Joint-Tape-2000/2000-S. With
structural movement joints, which penetrate the slab,<br />
lay the ASO-Joint-Tape-2000/2000-S in a loop.<br />
Alternative to the ASO waterproof tape system<br />
(production of a mineral-based coved fillet):<br />
Slurry coat the substrate with AQUAFIN-1K and whilst<br />
still wet construct a coved fillet of minimum side length<br />
4 cm, using ASOCRET-RN or a cement mortar (MGIII)<br />
with the addition of ASOPLAST-MZ. To protect against<br />
rear moisture ingress coat the area min. 20 cm<br />
above the foundation slab with AQUAFIN-RS300 or<br />
AQUAFIN-2K/M and continue down min. 10 cm<br />
over the front edge of the slab. Where there is exposure<br />
to standing seepage water/water under pressure,<br />
the waterproofing must be continued down for a<br />
min. 15 cm.<br />
Penetrations:<br />
Prepare the area around the penetration and bond<br />
an ADF pipe gasket or ADF floor gasket with<br />
AQUAFIN-RS300 or AQUAFIN-2K/M and once fully<br />
dried, blend in with the surface waterproof membrane.<br />
Where there is exposure to seepage water not under<br />
pressure or standing seepage water, use a bonded,<br />
lapped or integral flange and blend in with the<br />
waterproof membrane.<br />
Transition between splash contact / skirting area:<br />
In the area where there is splash water contact, continue<br />
the waterproofing to a minimum of 30 cm above<br />
the ground. Dependent on the ground contours, the<br />
waterproofing must reach a minimum of 15 cm above<br />
the top edge of the ground. As a rule this transition is<br />
coated with a flexible mineral-based waterproof slurry<br />
such as e.g. AQUAFIN-RS300 in order to produce<br />
a bonding substrate for e.g. skirting renders etc. The<br />
polymer modified bitumen coating is overlapped here<br />
by a min. 10 cm.<br />
Product preparation:<br />
COMBIFLEX-<strong>C2</strong>/S is sprayed using suitable equipment<br />
such as e.g. HighPump M8 (peristaltic pump).<br />
Information can be obtained from HTG HIGH TECH<br />
Germany GmbH, Berlin, www.hightechspray.de.<br />
Without priming, apply COMBIFLEX-<strong>C2</strong>/S according<br />
to the relevant manuals. Apply the thickness appropriate<br />
to the severity of the wet duty conditions homogenously.<br />
With applications against pressure water, a two coat<br />
application is necessary. We recommend to apply an<br />
ASO-Systemvlies-02 onto the fresh COMBIFLEX-<strong>C2</strong>/S<br />
without overlaps and to smooth off with either a steel<br />
float or tar brush. The ASO-Systemvlies-02 is generally<br />
used with concrete structures.<br />
External waterproofing in strips of concrete joints:<br />
The waterproofing is applied in strips onto the clean<br />
surface, minimum width 15 cm on both sides of the<br />
joint. The waterproofing is applied in two coats with a<br />
material consumption of 6.0 l/m². Into the first coat a<br />
reinforcing fabric is to be placed. The second coat can<br />
applied when the previous is not to become damaged.<br />
Onto the fresh finished layer an ASO-Systemvlies-02<br />
is to be laid. In the wall/floor transition area the<br />
waterproofing is to be continued down for a min.<br />
15 cm. at the front side.<br />
Checking the waterproof membrane:<br />
Checking and documenting the film thickness must<br />
always be carried out. If used against standing seepage<br />
water and pressure water a measurement of wet and<br />
dry film thickness should be carried out and recorded.<br />
The thickness checks are carried out whilst still wet by<br />
measuring the wet film thickness (recommended: min.<br />
20 measurements per site or min. 20 measurements for<br />
100 m). The spread of the measurement points should<br />
be diagonal. Dependent on structural factors, increase<br />
the measurements around penetrations, transitions,<br />
connections/junctions.<br />
Drainage and protection boards:<br />
Waterproof membranes are to be protected from<br />
weathering and mechanical damage by suitable<br />
protective measures or coatings. Protective layers may<br />
not exert any point or linear loading on the membrane.<br />
Therefore dimpled or corrugated sheets are not suitable.<br />
Only install protective layers once the waterproof<br />
membrane has fully dried out. Protective and drainage<br />
boards (e.g. INA Schutz- und Drainelement) can<br />
be fixed on liquid battens with COMBIDIC-2K with<br />
perimeter insulation being fully bedded and butt jointed.
Back-filling the building pit:<br />
Back-filling the building pit is carried out once the high<br />
build bitumen coating has fully dried out. Filling must<br />
be in accordance with relevant guidelines. The backfill<br />
material is to be introduced in layers and compacted.<br />
Ensure that the protective layer is not damaged or does<br />
not slip.<br />
Advice:<br />
• Protect areas not being treated with<br />
COMBIFLEX-<strong>C2</strong>/S.<br />
• Bitumen coatings cannot stand negative hydrostatic<br />
pressure. In areas where this is expected, a protective<br />
coating of AQUAFIN-1K must first be applied.<br />
• Protect masonry work capping and open window<br />
parapets from penetrating water.<br />
• In accordance with recognised technical<br />
regulations undertake waterproofing measures with<br />
AQUAFIN-RS300 or AQUAFIN-2K/M beneath rising<br />
walls and on the base slab.<br />
• The required wet film thickness may not be exceeded<br />
by 100% and may not fall below the required<br />
minimum at any point.<br />
• Protect COMBIFLEX-<strong>C2</strong>/S from weathering e.g. rain,<br />
frost, strong sunshine etc., until fully dried out.<br />
• This data sheet has been compiled based on<br />
SCHOMBURG factory specifications.<br />
Please observe a current valid EU Health &<br />
Safety Data Sheet.<br />
GISCODE: BBP 10<br />
This technical data sheet does not consider local building codes or legal requirements. It shall be used as general reference for the product, based on our current knowledge<br />
and experience. Legally binding is only the latest Data Sheet from one of our foreign subsidaries inside their sales territory. In any case of uncertainty please consult our<br />
technical department for further information.<br />
03/13 SF/CoS/PE/JD