Technical Data Sheet<br />

COMBIFLEX ® -<strong>C2</strong>/S Art.-No. 2 05017<br />

Two component high build bitumen coating<br />

for spray application (to factory specification)<br />

Properties:<br />

• Seamless, jointless, flexible<br />

crack-bridging waterproof<br />

membrane<br />

• Suitable for all conventional<br />

substrates<br />

• Can also be used on matt<br />

damp substrates without<br />

priming<br />

• Quickly rainproof<br />

• Rapid curing<br />

• Simple and efficient application<br />

• Radon barrier<br />

• Cationic emulsified<br />

• Solvent free<br />

• Waterproof material to DIN 18195-2<br />

• Certified for waterproofing of concrete<br />

joints in strips<br />

Areas of application:<br />

COMBIFLEX-<strong>C2</strong>/S is suitable for waterproofing ground<br />

covered building components such as e.g. cellar walls,<br />

foundations, floor slabs or screeds, dependent on the<br />

severity of the wet duty conditions:<br />

• Ground moisture<br />

• Seepage water<br />

• Pressure water<br />

Technical Data:<br />

Basis:<br />

Application/substrate<br />

temperature:<br />

P-2002-4-125/02<br />

bautest Dresden<br />

2 component polymer<br />

modified high build bitumen<br />

coating<br />

+5° C to +35° C<br />

Lower temperatures extend,<br />

higher temperatures reduce<br />

curing times<br />

Reaction time: approx. 10 sec.<br />

Crack bridging: min. 2 mm to DIN 28052-6<br />

Water impermeability: passed to DIN 52123<br />

(slit pressure 1mm)<br />

Material consumption:<br />

• Ground moisture, non-standing seepage water:<br />

4.0 l/m² = approx. 2.5 mm dry film thickness<br />

• Standing seepage water:<br />

6.0 l/m² = approx. 4.0 mm dry film thickness<br />

Greater material consumption for uneven substrates<br />

is not considered.<br />

Packaging:<br />

Storage:<br />

Cleaning materials:<br />

28, 180 and 1000 l<br />

containers<br />

6 months when stored frost<br />

free in the original unopened<br />

containers. Use opened<br />

containers promptly.<br />

Clean tools immediately with<br />

water or AQUAFIN-Cleanser.<br />

Dried on material can only be<br />

removed with difficulty.<br />

Substrate preparation:<br />

The substrate must be frost free, load bearing, flat with<br />

an open-pored texture and have a closed surface.<br />

It must be free from gravel pockets, cavities, gaping<br />

cracks, ridges and be free from adhesion inhibiting<br />

substances such as dust, laitance and loose parts.<br />

Undulations > 5 mm as well as mortar pockets,<br />

rendering grooves in brickwork or dense concrete<br />

blocks, open masonry work joints, voids, substrates with<br />

large pores or uneven masonry work are to be levelled<br />

up beforehand. Corners and edges are to be rounded<br />

or, with concrete sections, to be chamfered post<br />

installation. Mechanically remove laitance at the wall/<br />

floor transition.<br />

Internal corners, wall/floor junctions,<br />

separating joints:<br />

Apply AQUAFIN-RS300 or AQUAFIN-2K/M by brush<br />

or with a 4-6 mm notched trowel to the prepared<br />

substrate at a width 2 cm wider than the joint tape.<br />

Then, without folds or voids, lay the ASO-Joint-Tape-<br />

2000/2000-S into the fresh coat. The joint tape must<br />

be bonded in such a way as to exclude water migration<br />

to the rear of the ASO-Joint-Tape-2000/2000-S. With


structural movement joints, which penetrate the slab,<br />

lay the ASO-Joint-Tape-2000/2000-S in a loop.<br />

Alternative to the ASO waterproof tape system<br />

(production of a mineral-based coved fillet):<br />

Slurry coat the substrate with AQUAFIN-1K and whilst<br />

still wet construct a coved fillet of minimum side length<br />

4 cm, using ASOCRET-RN or a cement mortar (MGIII)<br />

with the addition of ASOPLAST-MZ. To protect against<br />

rear moisture ingress coat the area min. 20 cm<br />

above the foundation slab with AQUAFIN-RS300 or<br />

AQUAFIN-2K/M and continue down min. 10 cm<br />

over the front edge of the slab. Where there is exposure<br />

to standing seepage water/water under pressure,<br />

the waterproofing must be continued down for a<br />

min. 15 cm.<br />

Penetrations:<br />

Prepare the area around the penetration and bond<br />

an ADF pipe gasket or ADF floor gasket with<br />

AQUAFIN-RS300 or AQUAFIN-2K/M and once fully<br />

dried, blend in with the surface waterproof membrane.<br />

Where there is exposure to seepage water not under<br />

pressure or standing seepage water, use a bonded,<br />

lapped or integral flange and blend in with the<br />

waterproof membrane.<br />

Transition between splash contact / skirting area:<br />

In the area where there is splash water contact, continue<br />

the waterproofing to a minimum of 30 cm above<br />

the ground. Dependent on the ground contours, the<br />

waterproofing must reach a minimum of 15 cm above<br />

the top edge of the ground. As a rule this transition is<br />

coated with a flexible mineral-based waterproof slurry<br />

such as e.g. AQUAFIN-RS300 in order to produce<br />

a bonding substrate for e.g. skirting renders etc. The<br />

polymer modified bitumen coating is overlapped here<br />

by a min. 10 cm.<br />

Product preparation:<br />

COMBIFLEX-<strong>C2</strong>/S is sprayed using suitable equipment<br />

such as e.g. HighPump M8 (peristaltic pump).<br />

Information can be obtained from HTG HIGH TECH<br />

Germany GmbH, Berlin, www.hightechspray.de.<br />

Without priming, apply COMBIFLEX-<strong>C2</strong>/S according<br />

to the relevant manuals. Apply the thickness appropriate<br />

to the severity of the wet duty conditions homogenously.<br />

With applications against pressure water, a two coat<br />

application is necessary. We recommend to apply an<br />

ASO-Systemvlies-02 onto the fresh COMBIFLEX-<strong>C2</strong>/S<br />

without overlaps and to smooth off with either a steel<br />

float or tar brush. The ASO-Systemvlies-02 is generally<br />

used with concrete structures.<br />

External waterproofing in strips of concrete joints:<br />

The waterproofing is applied in strips onto the clean<br />

surface, minimum width 15 cm on both sides of the<br />

joint. The waterproofing is applied in two coats with a<br />

material consumption of 6.0 l/m². Into the first coat a<br />

reinforcing fabric is to be placed. The second coat can<br />

applied when the previous is not to become damaged.<br />

Onto the fresh finished layer an ASO-Systemvlies-02<br />

is to be laid. In the wall/floor transition area the<br />

waterproofing is to be continued down for a min.<br />

15 cm. at the front side.<br />

Checking the waterproof membrane:<br />

Checking and documenting the film thickness must<br />

always be carried out. If used against standing seepage<br />

water and pressure water a measurement of wet and<br />

dry film thickness should be carried out and recorded.<br />

The thickness checks are carried out whilst still wet by<br />

measuring the wet film thickness (recommended: min.<br />

20 measurements per site or min. 20 measurements for<br />

100 m). The spread of the measurement points should<br />

be diagonal. Dependent on structural factors, increase<br />

the measurements around penetrations, transitions,<br />

connections/junctions.<br />

Drainage and protection boards:<br />

Waterproof membranes are to be protected from<br />

weathering and mechanical damage by suitable<br />

protective measures or coatings. Protective layers may<br />

not exert any point or linear loading on the membrane.<br />

Therefore dimpled or corrugated sheets are not suitable.<br />

Only install protective layers once the waterproof<br />

membrane has fully dried out. Protective and drainage<br />

boards (e.g. INA Schutz- und Drainelement) can<br />

be fixed on liquid battens with COMBIDIC-2K with<br />

perimeter insulation being fully bedded and butt jointed.


Back-filling the building pit:<br />

Back-filling the building pit is carried out once the high<br />

build bitumen coating has fully dried out. Filling must<br />

be in accordance with relevant guidelines. The backfill<br />

material is to be introduced in layers and compacted.<br />

Ensure that the protective layer is not damaged or does<br />

not slip.<br />

Advice:<br />

• Protect areas not being treated with<br />

COMBIFLEX-<strong>C2</strong>/S.<br />

• Bitumen coatings cannot stand negative hydrostatic<br />

pressure. In areas where this is expected, a protective<br />

coating of AQUAFIN-1K must first be applied.<br />

• Protect masonry work capping and open window<br />

parapets from penetrating water.<br />

• In accordance with recognised technical<br />

regulations undertake waterproofing measures with<br />

AQUAFIN-RS300 or AQUAFIN-2K/M beneath rising<br />

walls and on the base slab.<br />

• The required wet film thickness may not be exceeded<br />

by 100% and may not fall below the required<br />

minimum at any point.<br />

• Protect COMBIFLEX-<strong>C2</strong>/S from weathering e.g. rain,<br />

frost, strong sunshine etc., until fully dried out.<br />

• This data sheet has been compiled based on<br />

SCHOMBURG factory specifications.<br />

Please observe a current valid EU Health &<br />

Safety Data Sheet.<br />

GISCODE: BBP 10<br />

This technical data sheet does not consider local building codes or legal requirements. It shall be used as general reference for the product, based on our current knowledge<br />

and experience. Legally binding is only the latest Data Sheet from one of our foreign subsidaries inside their sales territory. In any case of uncertainty please consult our<br />

technical department for further information.<br />

03/13 SF/CoS/PE/JD