TeSys D<br />

Contactors<br />

0.5 to 125HP<br />

Connections<br />

■ screw ■ screw clamp clamp terminals terminals or connectors or connectors<br />

Rated Rated operational operational voltage voltage<br />

690 V 690 V<br />

Rated Rated operational operational current current Ie maxIe<br />

AC-3 max AC-3<br />

9 A 9 A<br />

12 A 12 A<br />

18 A 18 A<br />

25 A 25 A<br />

32 A 32 A<br />

Continuous Continuous current current @600V @600V max per max UL per / CSA UL / CSA<br />

20 A 20 A<br />

25 A 25 A<br />

32 A 32 A<br />

40 A 40 A<br />

50 A 50 A<br />

Horsepower Horsepower ratings ratings 115/120 115/120 V single V single phase phase 0.5 hp0.5 hp 1 hp 1 hp 1 hp 1 hp 2 hp 2 hp 2 hp 2 hp<br />

CSA / CSA UL ratings / UL ratings 220/230 220/230 V single V single phase phase 1 hp 1 hp 2 hp 2 hp 3 hp 3 hp 3 hp 3 hp 5 hp 5 hp<br />

208 V three 208 V phase three phase 2 hp 2 hp 3 hp 3 hp 5 hp 5 hp 7.5 hp7.5 hp 10 hp 10 hp<br />

240 V three 240 V phase three phase 2 hp 2 hp 3 hp 3 hp 5 hp 5 hp 7.5 hp7.5 hp 10 hp 10 hp<br />

480 V three 480 V phase three phase 5 hp 5 hp 7.5 hp7.5 hp 10 hp 10 hp 15 hp 15 hp 20 hp 20 hp<br />

600 V three 600 V phase three phase 7.5 hp7.5 hp 10 hp 10 hp 15 hp 15 hp 20 hp 20 hp 30 hp 30 hp<br />

Contactor Contactor type (1) type (1) LC1D09 LC1D09 LC1D12 LC1D12 LC1D18 LC1D18 LC1D25 LC1D25 LC1D32 LC1D32<br />

Reversing Reversing contactor contactor type (with type mechanical (with mechanical interlock) interlock) (1) (1) LC2D09 LC2D09 LC2D12 LC2D12 LC2D18 LC2D18 LC2D25 LC2D25 LC2D32 LC2D32<br />

■ spring ■ spring terminals terminals up to D32 up to only D32 only<br />

Add the Add number the number 3 before 3 before the voltage the voltage code. Example code. Example LC1D09G7 LC1D09G7 becomes becomes LC1D093G7 LC1D093G7<br />

■ ring ■ tongue ring tongue<br />

Add the Add number the number 6 before 6 before the voltage the voltage code. Example code. Example LC1D09G7 LC1D09G7 becomes becomes LC1D096G7 LC1D096G7<br />

■ slip-on ■ slip-on connectors connectors 2 x 6.35 2 x (power) 6.35 (power) and 1 and x 6.35 1 x (control) 6.35 (control) up to D12 up to only D12 only<br />

Add the Add number the number 9 before 9 before the voltage the voltage code. Example code. Example LC1D09G7 LC1D09G7 becomes becomes LC1D099G7 LC1D099G7<br />

(1) Catalog (1) Catalog number number to completed to be completed by adding by adding the coil the voltage coil voltage code from code the from table the below. table below. Example Example of complete of complete catalog catalog number: number: LC1D09G7. LC1D09G7.<br />

4<br />

LC1D183 LC1D186 LC1D189<br />

Standard Standard control control circuit circuit voltages voltages<br />

ac supply ac supply<br />

Volts Volts<br />

24 2442<br />

4248<br />

48110<br />

110 120 1208<br />

208 220 220230<br />

230 240 240380<br />

380 440 440480<br />

480575<br />

575 600 600<br />

Contactors Contactors LC1D09–D150 LC1D09–D150 (D09 through (D09 through D32 and D32 D150 and available D150 available with 50/60 with Hz 50/60 only) Hz only)<br />

50/60 Hz 50/60 Hz B7 B7 D7 D7 E7 E7 F7 F7 G7 G7 LE7 LE7 M7 M7 P7 P7 U7 U7 Q7 Q7 R7 R7 T7 T7 SC7 SC7 X7 X7<br />

50 Hz 50 Hz B5 B5 D5 D5 E5 E5 F5 F5 G5 G5 - - M5 M5 P5 P5 U5 U5 Q5 Q5 R5 R5<br />

60 Hz 60 Hz B6 B6 - - E6 E6 F6 F6 - - L6 L6 M6 M6 - - U6 U6 Q6 Q6 R6 R6 T6 T6 S6 S6 X6 X6<br />

dc supply dc supply<br />

Volts Volts<br />

12 1224<br />

2436<br />

3648<br />

4860<br />

60 72 72110<br />

110 125 125220<br />

220440<br />

440<br />

Contactors Contactors LC1D09–D65A LC1D09–D65A (coils with (coils integral with integral suppression suppression device device fitted as fitted standard) as standard)<br />

0.7–1.25 0.7–1.25 Uc Uc JD JD BD BD CD CD ED ED ND ND SD SD FD FD GD GD MD MD RD RD<br />

Contactors Contactors LC1D80 LC1D80<br />

0.85–1.1 0.85–1.1 Uc Uc JD JD BD BD CD CD ED ED ND ND SD SD FD FD GD GD MD MD RD RD<br />

0.75–1.2 0.75–1.2 Uc Uc JW JW BW BW CW CW EW EW - - SW SW FW FW - - MW MW - -<br />

Contactors Contactors LC1D115 LC1D115 and D150 and (coils D150 with (coils integral with integral suppression suppression device device fitted as fitted standard) as standard)<br />

0.75–1.2 0.75–1.2 Uc Uc - - BD BD - - ED ED ND ND SD SD FD FD GD GD MD MD RD RD<br />

Low consumption<br />

Low consumption<br />

Volts dc Volts dc 5 5 12 1220 2024 2448 48 110 110 120 120250<br />

250<br />

Contactors Contactors LC1D09–D32 LC1D09–D32 (coils with (coils integral with integral suppression suppression device device fitted as fitted standard) as standard)<br />

0.7–1.25 0.7–1.25 Uc Uc AL AL JL JL ZL ZL BL BL EL EL FL FL ML ML UL UL<br />

4<br />

4/4<br />

Other versions: please consult our Customer Care Centre.