<strong>Sensors</strong><br />

Distance: S80<br />

Specifications<br />

S80-MH-5-YL09-PPIZ<br />

S80-MH-5-YL09-NNIZ<br />

Direct Measurement Range 1 0.3 - 7m scalable √ √<br />

Digital Resolution 0.4mm √ √<br />

Linearity 0.3% √ √<br />

Temperature Drift ±0.6mm/ºC √ √<br />

Repeatability 2<br />

3mm @ 4m √ √<br />

7mm @ 7m √ √<br />

Switching Output Hysteresis 3 5mm √ √<br />

Power Supply 15 - 30 V DC (limit values) √ √<br />

Ripple 2Vpp max. √ √<br />

Current Draw 110mA max. @ 24V DC √ √<br />

Light Emission Red Laser 665nm, class 2 √ √<br />

Setting<br />

Indicators (On Control Panel)<br />

Indicators (On Front)<br />

Output Type<br />

SET push-button √ √<br />

+/- push-button √ √<br />

4-digit display √ √<br />

Yellow OUTPUT LED √ √<br />

Green OUTPUT STATUS LED √ √<br />

Green FAST mode LED √ √<br />

Yellow OUTPUT LED √ √<br />

Red ALARM LED √ √<br />

2 PNP or 2 NPN √ √<br />

4 - 20 mA analog √ √<br />

Output Current ≤ 100mA √ √<br />

Saturation Voltage ≤ 2V √ √<br />

Response Time<br />

Switching Frequency<br />

5ms (NORMAL) √ √<br />

1ms (FAST) √ √<br />

100Hz (NORMAL) √ √<br />

500Hz (FAST) √ √<br />

Timing Function Selectable between 5, 10, 20, 30, 40ms √ √<br />

Auxiliary Functions<br />

Synchronism (SYNC) √ √<br />

Keylock 4 √ √<br />

RS485 serial interface √ √<br />

Connection M12 8-pole connector √ √<br />

Electrical Protection class 2 √ √<br />

Mechanical Protection IP67 √ √<br />

Protection Devices A, B 5 √ √<br />

Housing Material aluminium √ √<br />

Lens Material Glass √ √<br />

Weight 330g max. √ √<br />

Operating Temperature -10 to +50ºC √ √<br />

Storage Temperature -25 to +70ºC √ √<br />

Reference Standard EN60947-5-2, EN60825-1, UL508 √ √<br />

1. On target 90% white<br />

2. In Normal mode with 5 ms response time<br />

3. Active with SYNC wire connected to + V DC for at least 1 s at powering<br />

4. Connector can be locked in two positions<br />

5. A - reverse polarity protection<br />

B - overload and short-circuit protection<br />

CAUTION<br />

DO NOT STARE INTO BEAM<br />

CLASS 2 LASER PRODUCT<br />

EN60825-1 (1994) - IEC825-1 (1993)<br />

Max.power < 1mW<br />

II3D<br />

665nm<br />

PLCs Operator Interfaces Automation Software Power Supplies <strong>Sensors</strong> Communication & Networking<br />