92.678/1<br />

<strong>EYZ</strong> <strong>101</strong>: EY3600-UPS, UPS for compact AS and field modules<br />

In the event of a mains power failure, the EY3600-UPS (uninterruptible power supply) guarantees an<br />

uninterrupted change-over to battery mode for a compact AS. At the same time, the UPS provides a<br />

back-up power supply of 24 V~ for the novaLink164, novaLink165 and novaLink170 field modules.<br />

There are four diagnostic LEDs (Power, AS UPS, EYY UPS and Fault) and two information outputs (for<br />

battery mode and alarm).<br />

Type Description Weight<br />

g<br />

<strong>EYZ</strong> <strong>101</strong> F001 EY3600-UPS 100<br />

Technical data<br />

Max. charge current 100 mA from 12 V/AS1 Ambient temp. 0...45 °C<br />

or 24 V~ Transport and storage temp. –25...70 °C<br />

Charge voltage 13,5 V Humidity 10...90 %rh<br />

Max. charge time for<br />

without condensation<br />

6 Ah battery 72 h Accumulator specifications Lead storage battery 12 V, 6 Ah<br />

Cuts out<br />

< 9,8 V<br />

Back-up power supply from 11,9 V Wiring diagram A07766<br />

Dimension drawing M02181<br />

Information outputs Battery mode, alarm Fitting instructions MV 505578<br />

Accessories<br />

0367887 001* Lead storage battery (12 V, 6 Ah)<br />

*) Dimension drawing or wiring diagram are available under the same number<br />

Complies with:-<br />

EMC directive 2004/108/EC EN 61000-6-1/ EN 61000-6-2<br />

EN 61000-6-3/ EN 61000-6-4<br />

Engineering notes<br />

Using a top-hat rail (EN 50022), the EY3600-UPS can be fitted in a motor control centre or anywhere<br />

in the installation, and linked to a lead storage battery (12 V, 6 Ah). When connecting, a slow-blow fuse<br />

of 3,15 A should be fitted in the battery line (negative pole). Ensure correct polarity of the battery. Batteries<br />

with a larger capacity than recommended may also be used. Please note that, since the charge<br />

current is limited to 100 mA, the charging period will be correspondingly longer. The charge current<br />

comes from either the AS or an external isolating transformer (24 V~).<br />

novaLink field module for back-up power supply: The input for the back-up power supply of the<br />

novaLink field module (terminals 31 & 32) is wired to the voltage output of the <strong>EYZ</strong> <strong>101</strong> F001 (terminals<br />

10 & 11). This voltage output provides 24 V~ in normal operation or 12 V in battery mode. To<br />

safeguard the EYY-UPS, an external supply of 24 V~ must be applied to terminals 8 & 9.<br />

Information outputs:<br />

1. The digital ‘Status’ output signal (terminal 13) goes to an AS DI and is low in the case of battery<br />

mode<br />

2. The digital ‘Alarm’ output signal (terminal 14) goes to an AS DI and is high in the case of an incorrect<br />

battery voltage.<br />

LED display and diagnostics<br />

AS Power green lights up Power 12 V from AS1<br />

AS UPS green lights up Battery OK (13,5 V)<br />

not lit<br />

Battery charge (100 mA max.)<br />

flashes Battery mode (AS has back-up power supply)<br />

EYY UPS green lights up 24 V~ mode<br />

not lit<br />

Battery mode not in operation<br />

flashes Battery mode (EYY has back-up power supply)<br />

Fault red lights up Battery voltage too low or too high<br />

(< 11 V or > 15,5 V)<br />

Sauter Systems 7192678003 02


92.678/2 <strong>EYZ</strong> <strong>101</strong><br />

Wiring<br />

Battery Terminal 1 negative – (dark blue)<br />

Terminal 2 positive + (red)<br />

Wire<br />

2,5 mm²<br />

Length max. 1,2 m<br />

Fuse<br />

Slow-blow, 3,15 A, negative pole, fitted next to battery<br />

AS Terminal 3 Earth (dark blue)<br />

Terminal 4 +12 V + (red)<br />

Wire<br />

2,5 mm²<br />

Length max. 1,2 m<br />

Terminal 7<br />

Length<br />

AS signal<br />

max. 1,2 m<br />

Transformer Terminal 8 Earth<br />

Terminal 9 Ls<br />

Wire<br />

1,5 mm²<br />

Length max. 1,2 m<br />

EYY Terminal 10 Earth<br />

Terminal 11 +12 V<br />

Wire<br />

2,5 mm²<br />

Information outputs Terminal 12 Earth<br />

Terminal 13 Status<br />

Terminal 14 Alarm<br />

Length max. 1,2 m<br />

Wiring diagram for <strong>EYZ</strong> <strong>101</strong> F001<br />

<strong>EYZ</strong> <strong>101</strong> F001<br />

EY3600 - UPS<br />

(Uninteruptable Power Supply)<br />

+ 12 V<br />

AS1<br />

battery off<br />

MM<br />

+ 12 V<br />

1 2 3 4 7<br />

8 9 10 11 12 13 14 15 16<br />

Ls<br />

EYY<br />

Status (battery mode)<br />

Alarm (battery fault)<br />

NC<br />

3,15 AT<br />

24 V~<br />

EN61558-2-6<br />

A07766d<br />

Sauter Systems 7192678003 02


<strong>EYZ</strong> <strong>101</strong> 92.678/3<br />

Example of wiring<br />

<strong>EYZ</strong> <strong>101</strong> F001<br />

EY3600 - UPS<br />

+ 12 V<br />

AS1<br />

Batt. Off<br />

+ 12 V<br />

MM<br />

EYY<br />

Status (Battery mode)<br />

Alarm (Battery fault)<br />

NC<br />

1 2 3 4 7<br />

Ls<br />

8 9 10 11<br />

12 13 14 15 16<br />

EYY 1 . . F202 (novaLink1. .)<br />

3,15 AT<br />

32<br />

31<br />

24 V~<br />

EN61558-2-6<br />

EYL 2 . . F. . (nova2 . .)<br />

1 ... 15 novaLink<br />

N<br />

230 V~<br />

L<br />

PE<br />

100<br />

<strong>101</strong><br />

Power<br />

Receive<br />

Send<br />

1<br />

Power<br />

2<br />

12 V<br />

On<br />

Off<br />

3<br />

Batt. Off<br />

B08350b<br />

Dimension drawing<br />

Accessories<br />

178,5<br />

43<br />

367887<br />

6,4<br />

4,7<br />

103<br />

0,8<br />

58,5<br />

151<br />

25,5<br />

17<br />

M02181a<br />

97,5<br />

94<br />

M04571a<br />

Sauter Systems<br />

Printed in Switzerland<br />

Right of amendment reserved<br />

N.B.: A comma between cardinal<br />

numbers denotes a decimal point<br />

© Fr. Sauter AG, CH-4016 Basle<br />

7192678003 02