5. Type R Interface <br />
<br />
Command Code2216h Data Length19bytes<br />
Input and Output Port Function <br />
DAT No Function Setting range Initial value(hex) Setting unit<br />
DAT1 Input logic 0 Other than SELECT 0 On<br />
selection<br />
Active<br />
SELECT0Point 1PRG<br />
DAT2 Output logic 0 conn.On Active<br />
selection<br />
conn.<br />
DAT310 Input Port 015h 8,0,1,2,3,4,D,15 <br />
function<br />
DAT11 Output Port 029h 0,1,2,3,4,D,28,29,E <br />
19 function<br />
Sets the input / output signal logic of CN1, and selects the function of the generic input / output signals.<br />
DATA NO Function Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0<br />
DAT1 Input logic SEL STOP HL- HL+<br />
DAT2 Output logic ZONE ALM <br />
DAT3 Input function Allocates functions to each CN1 input PortIN1IN8.<br />
10<br />
Functions are to be selected from Chart 1.<br />
DAT11 <br />
19<br />
Output function Allocates functions to each CN1 output PortOut1Out9.<br />
Functions are to be selected from Chart 2.<br />
Points can be selected up to maximum of 128, but PEND output can be selected only up to 64<br />
Points.<br />
When either of Out8 or 9 is selected for the encoder signal output, both Out 8 and 9 will be encoder<br />
output. The selected function remain valid for other cases.<br />
<br />