4. Pulse Train Input Interface <br />

Command Code13486h<br />

Data Length0 byte<br />

Alarm History<br />

This command reads the current and past alarm history.<br />

Returned data<br />

Data length8Byte<br />

Data No<br />

Data1<br />

Data2-8<br />

Description<br />

Current alarm state<br />

Alarm historyin order of most recent to the oldest<br />

Abbreviation Code(Hex) Description<br />

No alarm Normal status<br />

DE Sensor disconnected<br />

OV Input power voltage is above the specification range<br />

MPE Input power voltage is below the specification range<br />

RSTE Initialization error (overload) / Power line disconnected<br />

OVF Position deviation abnormal<br />

OL Overload stop<br />

OS Overspeed<br />

RGOL Regeneration voltage is over the specified value<br />

ORG Zero-return error<br />

Wrap around Absolute position counter sign reversal<br />

LAE Lead angle error<br />

OC Overcurrent<br />

EEPER Non-volatile memory error<br />

Low voltage error when the power is OFF will not be stored in Alarm history.<br />