4. Pulse Train Input Interface <br />

Command Code226E2h<br />

Data Length2 bytes<br />

Control Switch Condition <br />

Data No Function Setting range Initial value Setting unit<br />

Data1 Control switching 0-FFh 2 2000PPSLSB<br />

frequency<br />

Data2 Current time constant 0-FFh 2 3A/255/0.5ms<br />

Control switching frequency is used to reduce the vibration caused at the time of slow motion operation.<br />

Set the frequency after referring to the recommended methods shown below.<br />

Normally, do not change the current time constant.<br />

Velocity differentiates depending on setting resolution.<br />

The torque generated below the set frequency will depend on Power Limit during stoppage.<br />

If the control switch is employed, please set it to 0.<br />

Recommended methods for use<br />

Control switch frequencySetting value×2000PPS<br />

During slow motion operationCommand frequency(PPS)<br />

During normal operationStart frequency+2000(PPS) <br />

Command frequency <br />

<br />

<br />

421