4. Pulse Train Input Interface <br />
Commands<br />
1 System commands<br />
Command Code01h<br />
Data Length0 byte<br />
Initialization<br />
Initializes the amplifier status to the power-up status.<br />
For parameter, the value of ROM is loaded to RAM.<br />
Command Code02h<br />
Data Length0 byte<br />
Parameter Clear<br />
Resets RAM parameters to their factory settings.<br />
Command Code03h<br />
Data Length0 byte<br />
Parameter Save<br />
Saves RAM parameters to the ROM.<br />
If a reset is performed without saving the parameters, the RAM values will be lost.<br />
Command Code04h<br />
Data Length0 byte<br />
Parameter Load<br />
Loads the parameters saved to ROM to RAM.<br />
The same operation is performed at power-up and when using the initialization command.<br />
RAM data is used when controlling.<br />
Command Code06h<br />
Data Length0 byte<br />
Alarm History Clear<br />
Clears the alarm history.<br />