5. Type R Interface <br />

3Operation<br />

i After the parameter setting is completed, turn the power off and connect wiring for the<br />

motor power and encoder.<br />

Refer to Chapter 3 to ensure the correct wiring.<br />

Perform safety check and attach the motor to the fixed plate etc. For safety, set up<br />

the emergency stop circuit before operating.<br />

ii) If the 7SEG LED writes an 8-shape after turning the power on, it is normal.<br />

<br />

Power start sequenceWhen the STOP input signal is cancelled<br />

Power voltage<br />

Initialization<br />

Approx.7V<br />

Rated voltage<br />

Initialization completion time5s max<br />

STOP<br />

SON Monitor<br />

SON<br />

Output signal status unstable time200msMax<br />

The output signal status is unstable for a maximum of 200ms after the power<br />

voltage reaches approximately 7V.<br />

Turn the power off after setting to STOP status, as low power voltage error may be<br />

detected when power is turned off with the servo ON.<br />