5. Type R interface <br />

5.4 Protection Function<br />

Alarm status is activated when an error in the system occurs.<br />

In the alarm status, the motor is in the fixed excitation state with the excitation current preset by<br />

Command 20h-DAT3. During motor operation, it enters the fixed excitation state after the motor<br />

is stopped at maximum torque.<br />

When the Power Limit during servo OFF status is set to 0, it enters the unexcited state.<br />

<br />

5.4.1 Alarm Description Confirmation<br />

Alarm description can be confirmed with 7 segment LED display or Communication (Command<br />

87h: Alarm history RD).<br />

Alarm<br />

Display Alarm description Recoverability<br />

abbreviation<br />

DE Sensor disconnected Unrecoverable<br />

OV Input power voltage is above the specification range Recoverable<br />

MPE Input power voltage is below the specification range Recoverable<br />

RSTE Initialization error / Power line disconnected Unrecoverable<br />

OVF Servo error Recoverable<br />

OL Overload stop Recoverable<br />

OS Over-speed Recoverable<br />

RGOL Regeneration voltage is over the specified value Recoverable<br />

ORG Zero-return error Recoverable<br />

CNT OVF Position command counter overflow Recoverable<br />

Wrap around Absolute position counter sign reversal Recoverable<br />

HSTOP Push error (wide swing) Recoverable<br />

LAE Lead angle error Unrecoverable<br />

OC Over-current Unrecoverable<br />

EEPER Non-volatile memory error Unrecoverable<br />

To cancel unrecoverable alarms, it is necessary to turn off the power, and then restart.<br />