5. Type R Interface <br />

Command Code64h<br />

Data Length4 bytes<br />

Zone JMP <br />

DAT No Function Setting range Initial value Setting unit<br />

DAT1 Jump condition 01 0Jumps to the specified line when out of the Zone range<br />

1Jumps to the specified line when in the Zone range<br />

DAT2 Target Zone No 03 <br />

DAT34 JMP target line Depends on PRG <br />

Number<br />

number<br />

This command sets the jump target according to the Zone output condition.<br />

<br />

Command Code10165h<br />

Data Length7 bytes<br />

Actual Position JMP <br />

DAT No Function Setting range Initial value Setting unit<br />

DAT1 Jump condition 01 0Jumps to the specified line when the<br />

condition does not match<br />

1Jumps to the specified line when the<br />

condition matches<br />

DAT25 Position coordinates Depends on resolution 1PULSE<br />

DAT67 JMP target line Number Depends on PRG number <br />

This command sets the jump target according to the current position condition (absolute position).<br />

Absolute travel distance setting range (Setting range depends on the resolution, as follows)<br />

Basic division setting 500 1000 2000 4000 5000 10000<br />

Pos. upper limit value 3333333 6666666 CCCCCCC 19999999 1FFFFFFF 3FFFFFFF<br />

Neg. upper limit value FCCCCCCD F999999A F3333334 E6666667 E0000001 C0000001<br />

<br />

Command Code10266h<br />

Data Length2 bytes<br />

Unconditional JMP <br />

DAT No Function Setting range Initial value Setting unit<br />

DAT12 JMP target line number Depends on PRG number <br />

This command sets the Jump target unconditionally.<br />

<br />

Command Code10367h<br />

Data Length3 bytes<br />

Motor Stop JMP <br />

DAT No Function Setting range Initial value Setting unit<br />

DAT1 Jump condition 01 0Jumps to the specified line during operation<br />

1Jumps to the specified line when the motor is stopped<br />

DAT23 JMP target line No. Depends on RPG No. <br />

This command specifies the jump target according to the motor stop status.<br />