5. Type R Interface <br />

<br />

Command Code9660h<br />

Data Length0 byte<br />

Program END <br />

This command ends the program. Program execution stops when the END command is encountered.<br />

Empty command lines are recognized as NOP and the program execution continues. It is<br />

necessary to always include the END command in the program.<br />

It is possible to have subroutines after the END command.<br />

<br />

Command Code9761h<br />

Data Length2 bytes<br />

Timer Wait <br />

DAT No Function Setting range Initial value Setting unit<br />

DAT12 Timer Wait 0FFFFh 1ms<br />

This command sets the delay timer value.<br />

This command is ignored during STEP operations.<br />

<br />

Command Code9862h<br />

Data Length3 bytes<br />

In-Position JMP <br />

DAT No Function Setting range Initial<br />

Setting unit<br />

value<br />

DAT1 Jump<br />

01 0Jumps to the specified line when out-position<br />

Condition<br />

1Jumps to the specified line when in-position.<br />

DAT2 JMP target line Depends on <br />

3 number PRG number<br />

Sets the jump target according to the In-Position condition set by former movement command.<br />

<br />

Command Code9963h<br />

Data Length4 bytes<br />

In-Port JMP <br />

DAT No Function Setting range Initial value Setting unit<br />

DAT1 Jump<br />

condition<br />

01 0Jumps to the specified line when condition does not<br />

match<br />

1Jumps to the specified line when condition matches<br />

DAT2 Input Port status 0FFh 0coupler OFF 1coupler On<br />

DAT34 JMP target line Depends on <br />

number PRG number<br />

This command sets the jump target according to the status of the generic input.<br />

DAT2 input port allocation<br />

Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0<br />

IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN1<br />

Only the port selected as generic input port by Command 16h can be the target.<br />