5. Type R Interface <br />

<br />

Command Code7349h<br />

Data Length0 byte<br />

Pause Clear <br />

This command cancels the Pause, and at the same time, moving to the target position resumes.<br />

If the Pause function is active at the input port, it will not be cancelled.<br />

<br />

Command Code744Ah<br />

Data Length0 byte<br />

Alarm Clear <br />

This command clears the alarm.<br />

Non-recoverable alarms are not cancelable; they can be cleared only by restarting the power, or<br />

using the initialization command.<br />

The command operates using an OR condition with the alarm clear signal of input port.<br />

<br />

Command Code754Bh<br />

Data Length2 bytes<br />

Bit Out <br />

DAT No Function Setting range Initial value(Hex) Setting unit<br />

DAT12 Bit Out 03Fh photocoupler OFF photocoupler ON<br />

Selects the output status of the generic output port.<br />

Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0<br />

OUT8 OUT7 OUT6 Out5 Out4 Out3 Out2 Out1<br />

Out9<br />

This command is valid only at Bid Out ports set for output port functions using command 16h. For<br />

<br />

output port other than Bif Out, this function will be ignored.<br />

Command Code764Ch<br />

Data Length0 byte<br />

STOP Command <br />

This command initiates an emergency stop. If the motor is in motion, it stops with the maximum<br />

possible deceleration rate, and the amplifier status changes to servo OFF.<br />

The command operates using an OR condition with the STOP input port.<br />

If used during program execution, the program execution will stop.<br />

<br />

Command Code774Dh<br />

Data Length0 byte<br />

STOP Clear <br />

Cancels the STOP initiated by a STOP command. At the time of the STOP clear, the amplifier status<br />

automatically changes to servo ON. This command does not clear the STOP signal at an input port.<br />

<br />