SANMOTION R Medium Capacity (200VAC, 750W to 15kW)
SANMOTION R Medium Capacity (200VAC, 750W to 15kW)
SANMOTION R Medium Capacity (200VAC, 750W to 15kW)
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
-<br />
External Wiring Diagram<br />
Single-Axis Servo Amplifier With CANopen<br />
Main Power : 200V ACControl Power : 200V ACDC24V<br />
Con<strong>to</strong>rol Power DC24V<br />
3-phase<br />
AC power<br />
200 <strong>to</strong> 230V<br />
5060Hz<br />
Note 10)<br />
MC<br />
Operation Prep.<br />
ON Operation Prep.<br />
OFF<br />
MC<br />
MC<br />
Emergency<br />
System Error<br />
S<strong>to</strong>p<br />
User Unit<br />
50A : CNA<br />
100 <strong>to</strong> 300A : Terminalblock<br />
Note 11)<br />
CNB<br />
T<br />
S<br />
R<br />
DC24V<br />
24V<br />
24G<br />
Con<strong>to</strong>rol Power AC200V<br />
User Unit<br />
1<br />
2<br />
Note 2)<br />
Note 3)<br />
Note 4)<br />
CNB<br />
Regenerative<br />
resis<strong>to</strong>r<br />
3-phase<br />
AC power<br />
200 <strong>to</strong> 230V<br />
5060Hz<br />
Note 10)<br />
MC<br />
50A : CNA<br />
100 <strong>to</strong> 300A : Terminalblock<br />
T<br />
Note 11) S<br />
R<br />
t<br />
r<br />
DL1<br />
DL2<br />
P<br />
RB1<br />
RB2<br />
+<br />
Operation Prep.<br />
ON<br />
Operation Prep.<br />
OFF<br />
MC<br />
MC<br />
Emergency<br />
System Error<br />
S<strong>to</strong>p<br />
CAN_H<br />
CAN_L<br />
Termina<strong>to</strong>r<br />
GND<br />
GND<br />
CN3<br />
1<br />
2<br />
5<br />
3<br />
7<br />
Note 12)<br />
SERVO AMPLIFIER<br />
CAN<br />
TRANCEIVER<br />
W<br />
V<br />
U<br />
50A : CNC<br />
100 <strong>to</strong> 300A : Terminalblock<br />
Note 6)<br />
Black<br />
White<br />
Red<br />
Green<br />
(Green/Yellow)<br />
SERVO MOTOR<br />
Orange<br />
(Yellow)<br />
Orange<br />
(Yellow)<br />
RY1<br />
Holding brake<br />
(for the type with<br />
a brake only)<br />
90V<br />
(24V)<br />
CAN_H<br />
CAN_L<br />
Termina<strong>to</strong>r<br />
SH<br />
Combination of<br />
Plug:TM21P-88P<br />
CN4<br />
1<br />
2<br />
5<br />
1/4W 120<br />
CN2<br />
Note 7)<br />
Note 5)<br />
Encoder connec<strong>to</strong>r<br />
SH<br />
Combination of<br />
SH<br />
Plug : 10120-3000PE<br />
Shell : 10320-52A0-008<br />
Encoder<br />
GND<br />
3<br />
GND<br />
7<br />
SH<br />
Combination of<br />
Plug:TM21P-88P<br />
SG<br />
CN1<br />
DC 3.6V<br />
Lithium Battery<br />
1<br />
BTP-I<br />
2<br />
8<br />
BTN-I<br />
NPN Output<br />
OUT-PWR<br />
14<br />
DC5V, Note 8)<br />
DC12V<br />
24V<br />
PNP Output<br />
OUT-PWR<br />
14<br />
Note 8)<br />
DC12V<br />
Note 8 )<br />
DC5V <strong>to</strong> 24V<br />
9<br />
3<br />
CONT<br />
-COM<br />
CONT1<br />
OUT1<br />
6<br />
OUT1<br />
6<br />
10 CONT2<br />
OUT2<br />
13<br />
OUT2<br />
13<br />
OUT-COM<br />
7<br />
4 CONT3<br />
SH<br />
Note 5)<br />
SH<br />
Note 5)<br />
11 CONT4<br />
Note 1) 1) For For the the parts parts markde markde , use , use a twisted a twisted pair shielded pair shielded cable. cable.<br />
5 CONT7<br />
12 CONT8<br />
Combination of<br />
Plug : 10114-3000PE<br />
Shell : 10314-52A0-008<br />
Note 2)When using an an external regenetive resis<strong>to</strong>r, resis<strong>to</strong>r, connect connect it between it between RB1 and RB1 2. If RB1 and 2. If RB1<br />
and 2are connected <strong>to</strong> the <strong>to</strong> the internal internal amplifier's amplifier's resis<strong>to</strong>r, resis<strong>to</strong>r, if a shorting if a shorting bar is bar is<br />
connected between between RB1and RB1and 4, first 4, first disconnect disconnect them. them.<br />
Note 3) The DL1 and DL2 terminals are for connecting a DC reac<strong>to</strong>r. If a DC reac<strong>to</strong>r is not<br />
Note 3) used, The DL1 short and the DL2 DL1 and terminals DL2 terminals are for using connecting the short a DC bar reac<strong>to</strong>r. supplied. If a DC reac<strong>to</strong>r is not<br />
used, short the DL1 and DL2 terminals using the short bar supplied.<br />
Note 4) The terminal and the P terminal are for maintenance (high-voltage circuit).<br />
Note 4) The terminal and the P terminal are for maintenance (high-voltage circuit).<br />
Note 5) Refer <strong>to</strong> the Instruction Manual for instructions on the shielding process.<br />
Note 5) Refer <strong>to</strong> the Instruction Manual for instructions on the shielding process.<br />
Note 6) The mo<strong>to</strong>r-side connection depends on the mo<strong>to</strong>r specification. The red, white,<br />
Note 6) black The mo<strong>to</strong>r-side green and orange connection markings depends are for on use the with mo<strong>to</strong>r lead type specification. mo<strong>to</strong>r power The line red, and white,<br />
brake line. Refer <strong>to</strong> the mo<strong>to</strong>r specifications for cannon plug type connections.<br />
black green and orange markings are for use with lead type mo<strong>to</strong>r power line and<br />
Note 7) Refer brake <strong>to</strong> line. the encoder Refer <strong>to</strong> connection the mo<strong>to</strong>r diagram specifications regarding for the cannon encoder plug connec<strong>to</strong>r type connections.<br />
wiring.<br />
Note 8) 7) Power Refer should <strong>to</strong> the be encoder supplied connection by the user. diagram Either of regarding the inputs can the be encoder selected. connec<strong>to</strong>r wiring.<br />
Note 9) 8) R,S,T,t,r,,P,DL1,DL2,RB1,RB2,U,V,W Power should be supplied by the are user. high-voltage Either of circuits, the inputs all other can be lines selected. are<br />
low-voltage. Ensure sufficient distance between the high- and low-voltage circuits.<br />
Note 9) R,S,T,t,r,,P,DL1,DL2,RB1,RB2,U,V,W are high-voltage circuits, all other lines are<br />
Note 10) It low-voltage. is recommended Ensure <strong>to</strong> use sufficient a ground distance fault interrupter between conforming<strong>to</strong> the high- and the UL, low-voltage IEC and circuits.<br />
EN standards.<br />
Note Note 11) 10) Do It is not recommended wire the S phase <strong>to</strong> for use a single-phase a ground fault power interrupter amplifier. conforming<strong>to</strong> the UL, IEC and<br />
EN standards.<br />
Note 12) Insert RJ45 connec<strong>to</strong>r <strong>to</strong> which 1pin(CAN_H) and 5pin(Termina<strong>to</strong>r) are<br />
Note 11) short-circuited Do not wire the in CN3 S phase or CN4 for when a single-phase the termina<strong>to</strong>r power is necessary. amplifier.<br />
Note 12) Insert RJ45 connec<strong>to</strong>r <strong>to</strong> which 1pin(CAN_H) and 5pin(Termina<strong>to</strong>r) are<br />
short-circuited in CN3 or CN4 when the termina<strong>to</strong>r is necessary.<br />
23